Description du produit :
Qualtech Products : un professionnel du secteur MFFT Bar est un système avancé Minimum Film Forming Temperature Bar with a user-friendly Color Touchscreen Display to professionally determine:
- le Minimum Film Forming Temperature of paint, coatings, synthetic latex, emulsions, polymers, adhesives and related sample materials
- le Transition Temperature of liquid samples including melted glass, dispersion materials, enamel, synthetic resins and related samples
- le Stacking Capability et le Blocking Power of samples including coated papers, prints and foils
Ce professionnel Minimum Film Forming Temperature Bar is designed and engineered offering the newest microchip technology combined with a large Color Touchscreen Display, user-friendly programming, 16 high-precision Temperature Sensors and 16 Temperature Points, an advanced Test Platen made of Copper to offer an increased level of heat conductivity, real-time sample monitoring, an advanced Heating System, an advanced Cooling System, Continuous Temperature Readings across the Sample Platen, automatic heating & cooling, user-friendly application, user-friendly sample handling, user-friendly cleaning, integrated safety features, ergonomic design, reliable performance, longevity and much more.
This professional Automatic MFFT Bar with Touchscreen Display is designed and engineered in accordance with international test standards including:
- ASTM D2354 (Standard Test Method for Minimum Film Formation Temperature (MFFT) of Emulsion Vehicles)
- ASTM D7306 (Standard Practice for Testing Low Temperature Film-Formation of Latex Paints by Visual Observation)
- ISO 2115 (Plastics — Polymer dispersions — Determination of white point temperature and minimum film-forming temperature)
- ISO 4622 (Paints and varnishes — Pressure test for stackability)
- DIN 53366 (Testing of Plastic Films and sheeting – Determination of Blocking Strength)
- DIN 53787 (Testing Of Polymer And Copolymer Aqueous Dispersions; Determination Of The Minimum Temperature Of Film Formation And The White Point Temperature)
Paint and Coatings:
Le Minimum Film Forming Temperature of paint and coatings is the lowest temperature at which the sample uniformly coalesces when applied on a substrate as a thin film.
The standard test to professionally determine the Minimum Film Forming Temperature of paint and coatings suggests using a Minimum Film Forming Temperature Bar as specified in recognized international test standards.
Adhesives:
Le Minimum Film Forming Temperature de One-Pack Epoxy Adhesives is measured by applying the same test method as suggested for paint and coatings.
When testing Two-Pack Epoxy Adhesives a small piece of Aluminum Foil is placed on the Sample Platen prior the application of the sample to facilitate a user-friendly cleaning after the sample test when removing the sample.
Two-Pack Epoxy Adhesives don't indicate a Minimum Film Forming Temperature, however, the Minimum Cure Temperature can be determined by scraping the sample with a PVC Spatula.
Minimum Film Forming Temperature Bar - Caractéristiques :
- Les dernières technologies de microprocesseurs
- Large Color Touchscreen Display
- Advanced Minimum Film Forming Temperature Bar
- Professional Test Platen made of Copper offering an increased level of heat conductivity
- Real Time Monitoring
- Capteurs de température de haute précision
- Système de chauffage avancé
- Système de refroidissement avancé
- Small Footprint to save space whilst maintaining professional performance
- 16 Temperature Points
- Continuous Temperature Measurement across the Sample Platen
- Automatic Cooling and Heating
- Included Cube Film Applicator
- User-friendly Sample Application
- Programmation conviviale
- Manipulation des échantillons conviviale
- User-friendly Cleaning
- Fonctions de sécurité intégrées
- Haute exactitude et haute précision
- Conception ergonomique
- Performances fiables et longévité
- Engineered in accordance with international test standard including ASTM D2354, ASTM D7306, ISO 2115, ISO 4622, DIN 53366, DIN 53787
MFFT Bar – Specifications:
| Modèle | QPI-MFFT8800 |
|---|---|
| Les dernières technologies de microprocesseurs | Oui |
| Grand écran tactile couleur | Oui |
| Temperature Gradient Platen Material | Copper with a special surface for increased heat conduction & longevity |
| Temperature Measurement Points | 16 |
| Temperature Measurement Point Intervals | 20 mm |
| Test Channels | 6 |
| Plage de températures | -10°C to +60°C |
| Integrated Advanced Heating System | Oui |
| Integrated Automatic Cooling System | Oui |
| Real Time Test Monitoring | Oui |
| Temperature Gradient Platen Size | 438 mm x 200 mm |
| Programmation conviviale | Oui |
| Manipulation des échantillons conviviale | Oui |
| User-friendly Cleaning | Oui |
| Haute exactitude et haute précision | Oui |
| Fonctions de sécurité intégrées | Oui |
| Tension | 110 V 60 Hz et 220 V 50 Hz |
| Water | Standard Water Supply |
| Conception ergonomique | Oui |
| Performances fiables et longévité | Oui |
| Engineered in accordance with international test standards including ASTM D2354, ASTM D7306, ISO 2115, ISO 4622, DIN 53366, DIN 53787 | |
MFFT Bar – Included items:
- Minimum Film Forming Temperature Bar
- Accessoires
- Certificat de qualité
- Soigneusement calibré
- Certificat d'étalonnage
- Manuel d'utilisation
- Garantie prolongée
- Assistance à vie
Obtenez dès maintenant des informations sur les produits, les tarifs, l'assistance technique et les services professionnels.
L'un de nos spécialistes répondra à votre demande dans les plus brefs délais. Vous pouvez également nous contacter en utilisant les coordonnées de nos succursales aux États-Unis, en Australie ou au Royaume-Uni.