Descrição do produto:
Setor de Produtos Qualtech Aparelho de ensaio de deflexão térmica é uma precisão VICAT H.D.T Heat Distortio Temperature Tester para medir o Heat Deflection Temperature of samples at the touch of a button. The Heat Deflection Temperature is the temperature at which a sample deflects by a standard amount when applying a specified test load.
O Heat Deflection Temperature Test determines to which extent a sample can withstand specified test loads under specified temperatures. The VICAT H.D.T. Heat Distortion Test is suitable for a wide range of heat sensitive samples including plastic and rubber.
Isto Heat Deflection Temperature Tester is designed and engineered offering the newest microchip technology combined with a large LCD Display, an advanced Heating and Cooling System, high-precision Temperature Sensors, an integrated high-precision Deflection Analysis System, real time monitoring, high accuracy and high precision, a large Sample Area for up to three samples and simultaneous testing, user-friendly application, user-friendly programming, user-friendly sample handling, direct printing of test data and test curves, an ergonomic design, reliable performance, longevity and much more.
Este profissional Heat Deflection Temperature Tester is designed and engineered to measure the Heat Deflection Temperature of up to three samples simultaneously at the touch of a button for research and quality management and is suitable for a wide range of samples in the medical industry, the pharmaceutical industry, the chemical industry, the food industry, the paint industry, the printing ink industry and many more.
This Automatic Heat Deflection Temperature Tester is designed and engineered in accordance with international test standards including:
- ASTM D648 (Standard Test Method for Deflection Temperature of Plastics Under Flexural Load in the Edgewise Position)
- ISO 75:2020 (Plastics — Determination of temperature of deflection under load — Part 1: General test method)
- ISO 306 (Plastics — Thermoplastic materials — Determination of Vicat softening temperature (VST))
VICAT Softening Temperature Tester - Características:
- A mais recente tecnologia de microchips
- Advanced Cooling & Heating System
- Automatic VICAT Softening Temperature Test at the touch of a button
- Ecrã LCD a cores de grandes dimensões
- Sensores de temperatura de alta precisão
- Navegação intuitiva pelo menu
- Aplicação de fácil utilização
- Manuseamento de amostras de fácil utilização
- Calibração automática
- Test Temperature Range up to 300°C
- Temperature Display Resolution 0.1°C
- Deflection Range 0 mm – 1.5 mm
- Deflection Display Resolution 0.001 mm
- Alta exatidão e alta precisão
- Funcionalidades de segurança integradas
- Integrated Sample Data Memory
- Design ergonómico
- Desempenho fiável e durabilidade
- Engineered in accordance with international test standards including ASTM D648, ISO 75, ISO 306
H.D.T Heat Deflection Tester – Especificações:
| Modelo | QPI-HDT2800 | QPI-HDT5800 | QPI-HDT6800 |
|---|---|---|---|
| A mais recente tecnologia de microchips | Sim | Sim | Sim |
| Ecrã LCD de grandes dimensões | Sim | Sim | Sim |
| Deflection Range | 0 mm - 1.5 mm | 0 mm - 1.5 mm | 0 mm - 1.5 mm |
| Deflection Accuracy | ±0.001 mm | ±0.001 mm | ±0.001 mm |
| Intervalo de temperatura | RT - 300°C | RT - 300°C | RT - 300°C |
| Resolução do ecrã | 0,1 °C | 0,1 °C | 0,1 °C |
| Accuracy Temperature | ±0.5°C | ±0.5°C | ±0.5°C |
| Simultaneous Sample Test | Up to 4 Samples | Up to 6 Samples | Up to 8 Samples |
| Cooling System | Water Based Cooling | Water Based Cooling | Water Based Cooling |
| Heating System | Oil Based Heating | Oil Based Heating | Oil Based Heating |
| Test Stations | 4 | 6 | 8 |
| Calibração automática | Sim | Sim | Sim |
| Aplicação de fácil utilização | Sim | Sim | Sim |
| Programação intuitiva | Sim | Sim | Sim |
| Navegação intuitiva pelo menu | Sim | Sim | Sim |
| Manuseamento de amostras de fácil utilização | Sim | Sim | Sim |
| Alta exatidão e alta precisão | Sim | Sim | Sim |
| Funcionalidades de segurança integradas | Sim | Sim | Sim |
| Automatic VICAT Test at the touch of a button | Sim | Sim | Sim |
| Direct Printing of Test Data & Test Curves | Sim | Sim | Sim |
| Sample Data Memory | Sim | Sim | Sim |
| Alta exatidão e alta precisão | Sim | Sim | Sim |
| Design ergonómico | Sim | Sim | Sim |
| Desempenho fiável e durabilidade | Sim | Sim | Sim |
| Engineered in accordance with international test standards including ASTM D648, ISO 75, ISO 306 | |||
VICAT Heat Distortion Temperature Tester – Included items:
- VICAT Heat Deflection and Softening Temperature Tester
- Acessórios
- Certificado de Qualidade
- Cuidadosamente calibrado
- Certificado de Calibração
- Manual do utilizador
- Garantia Alargada
- Apoio vitalício
Obtenha agora informações sobre produtos, preços, assistência técnica e serviços profissionais.
Um dos nossos especialistas responderá à sua consulta em breve. Em alternativa, pode contactar-nos através dos dados de contacto da empresa nos EUA, na Austrália ou no Reino Unido.