Produktbeschreiwung:
Qualtech Produkter Industrie Hëtzt-Ofleedungstester ass eng Präzisioun VICAT H.D.T Heat Distortio Temperature Tester fir ze moossen Heat Deflection Temperature of samples at the touch of a button. The Heat Deflection Temperature is the temperature at which a sample deflects by a standard amount when applying a specified test load.
Déi Heat Deflection Temperature Test determines to which extent a sample can withstand specified test loads under specified temperatures. The VICAT H.D.T. Heat Distortion Test is suitable for a wide range of heat sensitive samples including plastic and rubber.
Dëst Heat Deflection Temperature Tester is designed and engineered offering the newest microchip technology combined with a large LCD Display, an advanced Heating and Cooling System, high-precision Temperature Sensors, an integrated high-precision Deflection Analysis System, real time monitoring, high accuracy and high precision, a large Sample Area for up to three samples and simultaneous testing, user-friendly application, user-friendly programming, user-friendly sample handling, direct printing of test data and test curves, an ergonomic design, reliable performance, longevity and much more.
Dëse professionelle Heat Deflection Temperature Tester ass entworf an konstruéiert fir ze moossen d' Heat Deflection Temperature of up to three samples simultaneously at the touch of a button for research and quality management and is suitable for a wide range of samples in the medical industry, the pharmaceutical industry, the chemical industry, the food industry, the paint industry, the printing ink industry and many more.
This Automatic Heat Deflection Temperature Tester is designed and engineered in accordance with international test standards including:
- ASTM D648 (Standard Test Method for Deflection Temperature of Plastics Under Flexural Load in the Edgewise Position)
- ISO 75:2020 (Plastics — Determination of temperature of deflection under load — Part 1: General test method)
- ISO 306 (Plastics — Thermoplastic materials — Determination of Vicat softening temperature (VST))
VICAT Softening Temperature Tester - Funktiounen:
- Déi neiste Mikrochip-Technologie
- Advanced Cooling & Heating System
- Automatic VICAT Softening Temperature Test at the touch of a button
- Grousst faarwegt LCD-Display
- Héichpräzis Temperatursensoren
- Benotzerfrëndlech Menü-Navigatioun
- Benotzerfrëndlech Uwendung
- Benotzerfrëndlech Probenhandhabung
- Automatesch Kalibrasioun
- Test Temperature Range up to 300°C
- Temperature Display Resolution 0.1°C
- Deflection Range 0 mm – 1.5 mm
- Deflection Display Resolution 0.001 mm
- Héich Genauegkeet & Héich Präzisioun
- Integréiert Sécherheetsfunktiounen
- Integrated Sample Data Memory
- Ergonomescht Design
- Zouverlässeg Leeschtung & Liewensdauer
- Engineered in accordance with international test standards including ASTM D648, ISO 75, ISO 306
H.D.T Heat Deflection Tester – Spezifikatiounen:
| Modell | QPI-HDT2800 | QPI-HDT5800 | QPI-HDT6800 |
|---|---|---|---|
| Déi neiste Mikrochip-Technologie | Jo | Jo | Jo |
| Grousst LCD-Display | Jo | Jo | Jo |
| Deflection Range | 0 mm - 1.5 mm | 0 mm - 1.5 mm | 0 mm - 1.5 mm |
| Deflection Accuracy | ±0.001 mm | ±0.001 mm | ±0.001 mm |
| Temperaturberäich | RT - 300 °C | RT - 300 °C | RT - 300 °C |
| Display-Opléisung | 0,1 °C | 0,1 °C | 0,1 °C |
| Genauegkeet Temperatur | ±0,5 °C | ±0,5 °C | ±0,5 °C |
| Simultaneous Sample Test | Up to 4 Samples | Up to 6 Samples | Up to 8 Samples |
| Cooling System | Water Based Cooling | Water Based Cooling | Water Based Cooling |
| Heating System | Oil Based Heating | Oil Based Heating | Oil Based Heating |
| Test Stations | 4 | 6 | 8 |
| Automatesch Kalibrasioun | Jo | Jo | Jo |
| Benotzerfrëndlech Uwendung | Jo | Jo | Jo |
| Benotzerfrëndlech Programméierung | Jo | Jo | Jo |
| Benotzerfrëndlech Menü-Navigatioun | Jo | Jo | Jo |
| Benotzerfrëndlech Probenhandhabung | Jo | Jo | Jo |
| Héich Genauegkeet & Héich Präzisioun | Jo | Jo | Jo |
| Integréiert Sécherheetsfunktiounen | Jo | Jo | Jo |
| Automatic VICAT Test at the touch of a button | Jo | Jo | Jo |
| Direct Printing of Test Data & Test Curves | Jo | Jo | Jo |
| Sample Data Memory | Jo | Jo | Jo |
| Héich Genauegkeet & Héich Präzisioun | Jo | Jo | Jo |
| Ergonomescht Design | Jo | Jo | Jo |
| Zouverlässeg Leeschtung & Liewensdauer | Jo | Jo | Jo |
| Engineered in accordance with international test standards including ASTM D648, ISO 75, ISO 306 | |||
VICAT Heat Distortion Temperature Tester – Included items:
- VICAT Heat Deflection and Softening Temperature Tester
- Zousätz
- Qualitéitszertifikat
- Virsiichteg kalibréiert
- Kalibrasiounszertifikaat
- Benotzerhandbuch
- Erweidert Garantie
- Liewenslaang Ënnerstëtzung
Kritt elo Informatiounen iwwer Produkter, Präisser, techneschen Support a professionnell Déngschter.
Ee vun eise Spezialisten wäert kuerz op Är Ufro äntweren. Alternativ kontaktéiert eis iwwer d'Firma-Informatiounen an den USA, an Australien oder am Vereenegte Kinnekräich.