Hutt Dir Är Detailer vergiess?

QUALTECH PRODUKTER INDUSTRIE

QUALTECH PRODUKTER INDUSTRIE

Testinstrumenter fir Faarwen a Beschichtungen

Reell Wäerter fir eis Clienten a Clientë

QUALTECH PRODUKTER INDUSTRIE

Ausrüstung fir industriell Produktioun

Maschinnen op industrieller Skala fir Produktiounslinnë

Zouverlässeg Ausrüstung fir Är Produkter

QUALTECH PRODUKTER INDUSTRIE

Chemikalien fir d'Faarweproduktioun

Pigmenter & Bindemëttel & méi

Chemikalien fir Är Produkter z'ënnerstëtzen

QUALTECH PRODUKTER INDUSTRIE

Reell Wäerter fir eis Clienten a Clientë

Zouverlässeg Qualitéit

Professionellen Service

QUALTECH PRODUKTER INDUSTRIE

Zouverlässeg Qualitéit

Héich Technologie

Professionellen Service

Virdrun
Nächst

Mellt Iech hei fir Updates a Neiegkeeten

Produktbeschreiwung:

Qualtech Produkter Industrie Quadratesch Applikator ass präzis konstruéiert Quadratesch Filmapplikator mat Reservoir fir d'professionell Uwendung vu Beschichtungen a Lackfilmer op Probeflächen a Substrater mat aacht verschiddene Spaltgréissten.

Dëse professionelle Quadruplex-Filmapplikator Bitt aacht verschidde, präzis entworfene Spaltgréissten a ass ideal fir net-rigid Proben, déi eng zweeseiteg Opmaachung am Zentrum hunn.

Dëst mat héijer Präzisioun entwéckelt Quadratesch Filmapplikator Bitt Flexibilitéit, eng benotzerfrëndlech Uwendung an héich Präzisioun, andeems véier verschidde fiicht Filmdicke an engem eenzege Filmapplikator kombinéiert ginn. D'fortgeschratt Konstruktioun bitt exzellent Resultater, besonnesch bei saure a basesch Proben.

Dëse professionelle Applikator mat véiereckege Rahmen ass ideal fir manuell a automatesch Filmapplikatioun a Kombinatioun mat dem Automatesch Filmapplikator.

Dëst Filmapplikator fir e Quadratrahmen ass an engem grousse Spektrum vu verschiddene Gréissten verfügbar, déi verschidde Spaltgréissten ubidden, fir Är Ufuerderungen fir Fuerschung an Qualitéitsmanagement optimal ze erfëllen.

Dëse professionelle Square Film Applicator ass entworf an entwéckelt am Aklang mat internationalen Testnormen, dorënner:

Precision Square Film Applicator QPI‑CA Series – Uwendung:

ASTM Test Method D823

Zil

The ASTM D823 procedure defines how to produce uniform wet films of coatings for laboratory evaluation. It ensures repeatable film thickness and surface quality for tests such as gloss, adhesion, hardness, and drying time.

Apparat

  • Precision Square Film Applicator QPI‑CA Series — high‑grade stainless‑steel applicator equipped with analog or digital micrometer heads for precise gap adjustment.

  • Test substrate — glass, metal, or sealed paper panels cleaned and prepared according to coating type.

  • Drawdown surface — level, vibration‑free bench or automated film‑application platform.

Verfaren

Virbereedung

  • Mix the coating thoroughly and condition it to the test temperature (typically 23 ± 2 °C).

  • Clean the substrate with solvent or a lint‑free cloth.

Gap Adjustment

  • Set the micrometer heads to the desired film thickness (e.g., 50 µm, 100 µm, 150 µm).

  • Verify parallel alignment of the blade using calibration blocks.

Film Application

  • Deposit a measured amount of coating in front of the blade.

  • Draw the applicator smoothly across the substrate at a constant speed (150–300 mm/s).

  • Avoid vibration or jerking motion.

Drying and Evaluation

  • Allow the film to level and dry under controlled conditions.

  • Measure wet and dry film thickness using a calibrated gauge.

Key Parameters

  • Film uniformity tolerance: ± 2 µm for gaps ≤ 100 µm.

  • Wiederhuelbarkeet: within 1 % of target thickness.

  • Surface finish: free of streaks, bubbles, or edge lift.

Engineering Insight

The ASTM method emphasizes mechanical precision an consistent drawdown speed. The QPI‑CA’s micrometer control enables engineers to reproduce identical coating thicknesses across multiple samples, ensuring reliable comparative data for formulation and quality studies.

 

ISO Test Method ISO 2808

Zil

ISO 2808 specifies standardized techniques for measuring and controlling film thickness of paints, varnishes, and related coatings. When used with a micrometer‑adjustable applicator, it defines how to achieve and verify uniform wet films for laboratory testing.

Apparat

  • Precision Square Film Applicator QPI‑CA Series — adjustable doctor‑blade applicator with precision micrometer heads for controlled gap settings.

  • Reference substrate — glass or metal panels conforming to ISO 1514.

  • Thickness measurement tools — wet‑film combs or electronic gauges calibrated per ISO 2178 or ISO 2360.

Verfaren

Kalibrasioun

  • Confirm the micrometer gap using certified feeler gauges or calibration blocks.

  • Record nominal gap settings and environmental conditions.

Film Application

  • Apply the coating evenly across the substrate using the QPI‑CA applicator at a controlled speed.

  • Maintain constant pressure and angle to ensure uniform flow.

Thickness Verification

  • Immediately measure wet film thickness at multiple points.

  • After drying, measure dry film thickness and compare to theoretical values.

Reporting

  • Document gap setting, coating type, viscosity, substrate, ambient temperature, and humidity.

  • Calculate deviation between nominal and measured thickness.

Key Parameters

  • Measurement accuracy: ± 5 % of nominal thickness.

  • Environmental control: 23 ± 2 °C, relative humidity 50 ± 5 %.

  • Surface uniformity: no visible streaks or discontinuities.

Engineering Insight

The ISO method focuses on traceability and calibration. It ensures that every film produced with the QPI‑CA applicator can be correlated to certified measurement standards, supporting international quality assurance an cross‑laboratory reproducibility.

Precision Quadruplex Film Applicator - Features:

  • High-Precision Wet‑Film Thickness Control for laboratory drawdowns and standardized coating evaluations

  • High repeatability and reproducibility thanks to a finely adjustable micrometer‑controlled gap system

  • Uniform film formation with minimized streaking, bubbling, edge lift or surface defects

  • Optimized for ASTM and ISO coating procedures, including ASTM D823 and ISO 2808

  • Suitable for a broad range of coating materials such as paints, lacquers, inks, adhesives, polymers, sealants, and battery slurries

  • Robust stainless‑steel construction ensures excellent mechanical stability and long‑term dimensional accuracy

  • Consistent film quality on multiple substrates, including glass, metal, foil, composite panels and sealed paper

  • Delivered ready for immediate use, with fast installation and and instant application for efficient laboratory workflows

  • High durability and corrosion resistance, ideal for daily quality control and research environments

  • Enhanced leveling and adhesion behavior through exact gap control and stable blade geometry

  • Wide range of custom engineered Square Film Applicators optional available supporting thin and thick film applications up to 38 inch Maximum Wet Film Application Width

  • Premium stainless‑steel square doctor blade for smooth, even film deposition and long service life

  • Rigid, stable frame design ensures controlled manual drawdowns without vibration or flex

  • Available in multiple application widths from 80 mm - 1000 mm, including custom‑engineered dimensions

  • Ergonomic handling for comfortable, controlled drawdowns during repetitive testing

  • Easy cleaning and maintenance due to an open, accessible square‑frame design

  • Compatible with automatic film applicators, enabling standardized drawdown speeds and automated workflows

  • High precision and high accuracy, engineered for demanding laboratory environments

  • Reliable performance with ergonomic operation, suitable for extended daily use

  • Manufactured in accordance with international standards, including ASTM D823 and ISO 2808

Precision Quadruplex Applicator - Specifications:

Breet vun der fiichter Filmapplikatiounachtzeg Millimeter
Gesamtlängt100 mm

Square Coating & Film Applicator - Available Models:

ModellLückegrooss
QPI-SFA10,5 mils 1,0 mils 1,5 mils 2,0 mils 3,0 mils 4,0 mils 5,0 mils 6,0 mils
QPI-SFA21 mil 2 mil 3 mil 4 mil 5 mil 6 mil 7 mil 8 mil
QPI-SFA35 Milli 10 Milli 15 Milli 20 Milli 25 Milli 30 Milli 40 Milli 50 Milli

Advanced Square Film Applicator – Abegraff Saachen:

  • Professional Square Film Applicator
  • Schéin Transportkëscht
  • Kalibrasiounszertifikaat
  • Qualitéitszertifikat
  • Benotzerhandbuch
  • Erweidert Garantie
  • Liewenslaang Ënnerstëtzung

Kritt elo Informatiounen iwwer Produkter, Präisser, techneschen Support a professionnell Déngschter.
Ee vun eise Spezialisten wäert kuerz op Är Ufro äntweren. Alternativ kontaktéiert eis iwwer d'Firma-Informatiounen an den USA, an Australien oder am Vereenegte Kinnekräich.

Kuckt e puer vun eise geschätzte Clienten:

Laboratoire-Testinstrumenter
Uewen
Feeler: