Produktbeschreiwung:
Qualtech Produkter Industrie Karl-Fischer-Titrator ass eng Präzisioun Automatic Karl Fischer Titration System for the professional measurement of the Moisture Content an de Water Content of samples in accordance with the Volumetric Titration Method an de Volumetric Karl Fischer Method.
Dëse professionelle Automatic Volumetric Karl Fischer Titrator is engineered to measure the moisture content and the water content of samples within the full range with the Volumetric Karl Fischer Test Method.
Déi Karl Fischer Test Method is performed with two different Karl Fischer Titration Test Methods each offering advantages which might indicate which Karl Fischer Titration Test Method may be best suited for a specific Water Content Measurement Application:
- Volumetric Karl Fischer Titrator
- Koulometresche Karl-Fischer-Titrator
Déi Volumetric Karl Fischer Titration Method is usually best suited for samples with an expected Water Content of more than 1%. The Volumetric Karl Fischer Titrator requires a specialized Karl Fischer Reagent to perform the Water Content Analysis which has a specified titer which may change over time and requires frequent verification with a Calibrated Water Standard. De Volumetric Karl Fischer Method is less accurate compared to the Koulometresche Karl-Fischer-Titrator but is suitable for larger sample volumes.
Déi Coulometric Karl Fischer Titration Method is usually best suited for samples with an expected Water Content across the full range from 0.0% - 100.0% and offers a much higher accuracy compared to the Volumetric Karl Fischer Titrator, hence the Koulometresche Karl-Fischer-Titrator is also suitable for samples with a very low Water Content below 1%. Based on the high accuracy of the Colulometric Karl Fischer Titrator it is often referred to as the 'Absolute Karl Fischer Method'. De Coulometric Karl Fischer Sample Container has two compartments, one compartment is for the Anode, the second compartment is for the Kathode. De Volumetric Karl Fischer Titrator offers a higher accuracy and completes sample tests faster compared to the Volumetric Karl Fischer Titrator. In addition, the Koulometresche Karl-Fischer-Titrator doesn't require an ongoing calibration for the Karl Fischer Reagent an de Solvent doesn't need to be replaced after each sample tests allowing for possibly lower ongoing costs and a more convenient application.
Dëse professionelle Automatic Volumetric Karl Fischer Titrator offers the newest microchip technology for Volumetric Karl Fischer Titration combined with a closed system for advanced user safety, a large LCD Display with Backlight, a Non-Pollution System & Non-Leakage System, Fully-Automatic Sample Dispensing, Fully-Automatic Sample Discharge, Fully-Automatic Karl Fischer Reagent Dispensing, Automatic Cleaning, Advanced Safety Features, a wide range of integrated Automatic Titration Programs, a large integrated Sample Measurement Data Memory, comfortable Softtouch Buttons, user-friendly programming, user-friendly Menu Navigation, Advanced Real Time Monitoring, high accuracy, high precision, an ergonomic design, reliable performance, longevity and much more.
Dës Präzisioun Volumetric Karl Fischer Titrator is the recommended Moisture Measurement Instrument for research and quality management including chemical laboratories, pharmaceutical laboratories, petrochemical laboratories, food test laboratories, agricultural laboratories, cosmetic laboratories and many more.
Dëse professionelle Karl-Fischer-Titrator is designed and engineered in accordance with the Volumetric Karl Fischer Titration Method two professional titration methods to measure the trace amount of water and moisture in samples.
The Karl Fischer Titration includes two Moisture Measurement Test Methods:
- Coulometric Karl Fisher Method
- Volumetric Karl Fisher Method
The main principles of both titration methods are related. The Coulometric Titration System is highly sensitive to moisture. It is ideal to determine the water content of samples as low as 0.1 µg and a moisture content of ≤ 200 µg. The Coulometric Titration Method offers highest precision and highest accuracy and is best suitable for samples with a very low moisture content in the range from 0.0% to 1.0%.
Déi Volumetric Titration System is less sensitive to moisture and water content compared to the Coulometric Titration System and is best suitable to determine a moisture content of samples with a higher water and moisture content in the range from 1% to 100%.
Dëst Automatic Volumetric Karl Fischer Titrator offers a wide range of practical advantages over other methods of moisture determination including automatic testing, user-friendly sample handling, high precision, high repeatability.
This professional Volumetric Karl Fisher Titrator is designed and engineered in accordance with international test standards including:
- ASTM D4377 (Standard Test Method for Water in Crude Oils by Potentiometric Karl Fischer Titration)
- ASTM D6869 (Standard Test Method for Coulometric and Volumetric Determination of Moisture in Plastics Using the Karl Fischer Reaction (the Reaction of Iodine with Water))
- ASTM E203 (Standard Test Method for Water Using Volumetric Karl Fischer Titration)
- ISO 15512 (Plastics — Determination of water content)
Volumetric Karl Fischer Titrator – Application:
Déi Karl-Fischer-Titrator ass eng Präzisioun Automatic Karl Fischer Titration System for the professional measurement of the Moisture Content an de Water Content of samples in accordance with the Volumetric Titration Method an de Volumetric Karl Fischer Method.
The professional Automatic Volumetric Karl Fischer Titrator is engineered to measure the moisture content and the water content of samples within the full range with the Volumetric Karl Fischer Test Method.
Déi Karl Fischer Test Method is performed with two different Karl Fischer Titration Test Methods each offering advantages which might indicate which Karl Fischer Titration Test Method may be best suited for a specific Water Content Measurement Application:
- Koulometresche Karl-Fischer-Titrator
- Volumetric Karl Fischer Titrator
Déi Volumetric Karl Fischer Titration Method is usually best suited for samples with an expected Water Content of more than 1%. The Volumetric Karl Fischer Titrator requires a specialized Karl Fischer Reagent to perform the Water Content Analysis which has a specified titer which may change over time and requires frequent verification with a Calibrated Water Standard. De Volumetric Karl Fischer Method is less accurate compared to the Koulometresche Karl-Fischer-Titrator but is suitable for larger sample volumes.
Déi Coulometric Karl Fischer Titration Method is usually best suited for samples with an expected Water Content across the full range from 0.0% - 100.0% and offers a much higher accuracy compared to the Volumetric Karl Fischer Titrator, hence the Koulometresche Karl-Fischer-Titrator is also suitable for samples with a very low Water Content below 1%. Based on the high accuracy of the Colulometric Karl Fischer Titrator it is often referred to as the 'Absolute Karl Fischer Method'. De Coulometric Karl Fischer Sample Container has two compartments, one compartment is for the Anode, the second compartment is for the Kathode. De Volumetric Karl Fischer Titrator offers a higher accuracy and completes sample tests faster compared to the Volumetric Karl Fischer Titrator. In addition, the Koulometresche Karl-Fischer-Titrator doesn't require an ongoing calibration for the Karl Fischer Reagent an de Solvent doesn't need to be replaced after each sample tests allowing for possibly lower ongoing costs and a more convenient application.
Dës Präzisioun Volumetric Karl Fischer Titrator is the recommended Moisture Measurement Instrument for research and quality management including chemical laboratories, pharmaceutical laboratories, petrochemical laboratories, food test laboratories, agricultural laboratories, cosmetic laboratories and many more.
The Karl Fischer Titration includes two Moisture Measurement Test Methods:
- Coulometric Karl Fisher Method
- Volumetric Karl Fisher Method
The main principles of both titration methods are related. The Coulometric Titration System is highly sensitive to moisture. It is ideal to determine the water content of samples as low as 0.1 µg and a moisture content of ≤ 200 µg. The Coulometric Titration Method offers highest precision and highest accuracy and is best suitable for samples with a very low moisture content in the range from 0.0% to 1.0%.
Déi Volumetric Titration System is less sensitive to moisture and water content compared to the Coulometric Titration System and is best suitable to determine a moisture content of samples with a higher water and moisture content in the range from 1% to 100%.
Dëst Automatic Volumetric Karl Fischer Titrator offers a wide range of practical advantages over other methods of moisture determination including automatic testing, user-friendly sample handling, high precision, high repeatability.
Advanced Karl Fischer Titrator – Features:
- Déi neiste Mikrochip-Technologie
- Volumetric Karl Fischer Method & Coulometric Karl Fischer Method
- Non-Pollution System & Non-Leakage System
- Fully-Automatic Sample Dispensing
- Fully-Automatic Sample Discharge
- Fully-Automatic Karl Fischer Reagent Dispensing
- Automatic Cleaning
- Select from a wide range of integrated Titration Programs
- Select from a wide range of Measurement Units including 'ppm', 'mg', 'mg/L', '%'
- Large Integrated Sample Measurement Data Memory Chip
- Bequeme Softtouch-Knäppercher
- Benotzerfrëndlech Programméierung
- Benotzerfrëndlech Menü-Navigatioun
- Fortschrëttlech Echtzäit-Iwwerwaachung
- Héich Genauegkeet & Héich Präzisioun
- Ergonomescht Design
- Zouverlässeg Leeschtung & Liewensdauer
- Engineered in accordance with international test standards including ASTM D4377, ASTM D6869, ISO 1522
Advanced Karl Fischer Titrator – Spezifikatiounen:
| Modell | QPI-VCT6800 |
|---|---|
| Déi neiste Mikrochip-Technologie | Jo |
| Volumetric Measuring Range | 0.1 mg - 250.0 mg |
| Coulometric Measuring Range | 10 µg - 20 mg |
| Volumetric Method Units | mg, mg/L, ppm, % |
| Coulometric Method Units | µg, µg/L, mg, mg/L, ppm, % |
| Polarization Current | 1 ±0.2 µA 50 ±10 µA |
| Electrolyt Current | 10 mA 20 mA 50 mA 100 mA |
| Accuracy Volumetric Test | ≤0.5% |
| Accuracy Coulometric Test | ≤3% |
| Automatic Titration Programs | Jo |
| Closed System for Advanced Safety | Jo |
| Non-Pollution System | Jo |
| Non-Leakage System | Jo |
| Fully-Automatic Sample Dispensing | Jo |
| Fully-Automatic Sample Discharge | Jo |
| Fully-Automatic Karl Fischer Reagent Dispensing | Jo |
| Automatic Cleaning | Jo |
| Spannung | 110 Volts 60 Hz & 220 Volts 50 Hz |
| Onaufwänneg PC-Verbindung & PC-Software | Jo |
| Ergonomescht Design & Zouverlässeg Leeschtung | Jo |
| Engineered in accordance with international test standards including ASTM D4377, ASTM D6869, ISO 1522 | |
Automatic Volumetric Karl Fischer Titrator – Abegraff Saachen:
- Automatic Volumetric Karl Fischer Titrator for Volumetric & Coulometric Test Method
- Virsiichteg kalibréiert
- Kalibrasiounszertifikaat
- Qualitéitszertifikat
- Benotzerhandbuch
- Erweidert Garantie
- Liewenslaang Ënnerstëtzung
Kritt elo Informatiounen iwwer Produkter, Präisser, techneschen Support a professionnell Déngschter.
Ee vun eise Spezialisten wäert kuerz op Är Ufro äntweren. Alternativ kontaktéiert eis iwwer d'Firma-Informatiounen an den USA, an Australien oder am Vereenegte Kinnekräich.