INDUSTRIE DES PRODUITS QUALTECH

INDUSTRIE DES PRODUITS QUALTECH

De vraies valeurs pour nos clients & clients

États-Unis : +1 720 897 7818
Royaume-Uni : +44 161 408 5668
UA : +61 2 8091 0618

Email : [email protected]

INDUSTRIE DES PRODUITS QUALTECH
2186 South Holly Street, Denver, Colorado 80222, États-Unis

Ouvrir dans Google Maps
  • Accueillir
  • Instruments
    • Mesure de viscosité
      • Gobelets Flow
        • Coupe d'écoulement ISO ASTM D5125 ISO 2431 DIN 53224 BS EN 535
        • Coupes Ford ASTM D333 ASTM D365 ASTM D1200 ISO 2431
        • Coupe Zahn ASTM D1084 ASTM D4212 BS EN 535
        • Coupe japonaise IWATA
        • Coupelle DIN DIN 53211
        • Tasse à pression ISO 2811-4 BS 3900-A22
        • Supports et supports pour coupes à débit de viscosité
      • Viscosimètre rotatif
        • Viscosimètre portatif
        • Viscosimètre portatif
        • Viscosimètre rotatif numérique
        • Viscosimètre à broche avec écran tactile
        • Viscosimètre Krebs Stormer
        • Viscosimètre haute température
        • Viscosimètre à cône et plaque
        • Bain de viscosité
        • Viscosimètre Laray
        • Viscosimètre Farine & Amidon
    • Test d'apparence
      • Brillant
        • Brillancemètre
        • Brillancemètre avec micro-lentille
        • Brillancemètre Haze
        • Brillancemètre Angle 45°
        • Brillancemètre Angle 75°
        • Glossmètre de poche
        • Brillancemètre avec écran tactile
        • Lecteur de couleur et compteur de brillance
        • Brillancemètre en ligne
        • Mini Brillancemètre
      • Transparence Brume Clarté
        • Compteur de brume
        • Turbidimètre portatif
        • Turbidimètre de bureau
      • Couleur
        • Lecteur couleur portable
        • Lecteur couleur portable
        • Lecteur couleur de paillasse
        • Spectrophotomètre portatif
        • Spectrophotomètre de bureau
        • Cabinet d'évaluation des couleurs
        • Station d'épreuvage couleur
        • Comparateur de couleurs Gardner
        • Teintemètre Lovibond
        • Cartes de couleurs RAL
        • Cartes de couleurs Pantone
        • Lecteur couleur portable pour liquides
        • Colorimètre portable pour poudres
        • Colorimètre portable pour produits pharmaceutiques
        • Logiciel de correspondance des couleurs
      • Blancheur
        • Compteur de blancheur portable
        • Compteur de blancheur portable
        • Mètre de blancheur de bureau d'OIN
        • Compteur de blancheur CIE D65
        • Appareil de mesure de la porosité
      • Épaisseur
        • Jauges d'épaisseur de film humide
        • Jauge d'épaisseur de film humide de roue
        • Jauge d'épaisseur de revêtement
        • Jauge d'épaisseur à ultrasons
        • Jauge d'inspection de la peinture
        • Jauge d'épaisseur de banane
        • Étrier
        • Mètre d'épaisseur de feuille
      • Opacité de réflexion
        • Compteur de réflectance
        • Réflectomètre spectral portatif
        • Réflectomètre de bureau
        • Cryptomètre numérique
        • Compteur de réflectance infrarouge
        • Compteur de transmission lumineuse
        • Compteur de transmission de lumière pour verre et lentille
        • Transmetteur de lumière 365nm & 550nm & 850nm & 940nm
        • Compteur de transmission de la lumière UV
        • Compteur de transmission de la lumière infrarouge
        • Compteur de transmission de la lumière bleue
        • Rétroréflectomètre à angle unique
        • Rétroréflectomètre multi-angle
    • Série d'applications
      • Coucheuse par trempage
      • Applicateur automatique de film sous vide
      • Applicateur de film automatique avec table d'application de film en acier inoxydable et en verre
      • Testeur de mise à niveau
      • Testeur SAG
      • Applicateurs de film
      • Enduiseur de barre de fil
      • Pistolet à peinture
      • Spin Coater
      • Table à vide pour application de film
      • Surface de rabattement
      • Graphiques en damier
      • Couche d'immersion d'azote
      • Couche d'immersion multicouche
      • Coucheuse à température constante
      • Casterguide pour applicateur de film cube
      • Chambre de pulvérisation de substrat automatique
      • Cabine de pulvérisation de lavage à l'eau
    • Mesure de l'humidité
      • Titreur Karl Fischer
      • Titreur coulométrique Karl Fischer
      • Humidimètre numérique
      • Analyseur d'humidité
      • Évaporateur rotatif
    • Test des propriétés physiques
      • Finesse de mouture
        • Jauges de finesse de mouture
        • Finesse électrique des jauges de mouture
      • Temps de séchage
        • Enregistreur de temps de séchage
        • Enregistreur de temps de séchage automatique
        • Testeur d'état à sec
      • Densité
        • Tasses de densité
        • Pycnomètre à gaz
        • Densimètre portatif
        • Densimètre de paillasse
        • Densitomètre portatif
        • Densitomètre à transmission
        • Densitomètre à transmission optique
        • Densimètre de flottabilité
        • Scott volumètre
        • Débitmètre Hall
        • Débitmètre Carney
        • Densimètre apparent ASTM D1895 Méthode A
        • Densimètre apparent ASTM D1895 Méthode B
        • Densimètre apparente ISO R60
        • Mètre de densité en vrac
        • Volumemètre de densité apparente
        • Tapez Densimètre
        • Angle de repos de la poudre
        • Testeur de caractéristiques de poudre
        • Système d'analyse automatique de la propreté du filtre
        • Pycnomètre Automatique à Densité Réelle
        • Débitmètre Gustavsson
        • Densimètre Arnold
        • Densimètre apparente Méthode ISO R60
        • Densimètre apparent ASTM D1895 Méthode A
        • Densimètre apparent ASTM D1895 Méthode B
        • Densimètre en vrac ASTM D1895 Méthode C
        • Densimètre automatique pour liquides
        • Densimètre pour liquides
        • Cabinet de confort acoustique
      • Conductivité et pH
        • pH-mètre de poche
        • pH-mètre portatif
        • pH-mètre portatif
        • pH-mètre de bureau
        • Conductimètre portatif
        • Conductimètre portable
        • Conductimètre et pH-mètre de bureau
        • Électrode pH
        • Électrode sélective d'ions
        • Électrode à oxygène dissous
        • Électrode de référence
        • Électrode de conductivité
        • Métal Électrode
        • Électrode de température
      • Réfraction
        • Réfractomètre portatif
        • Réfractomètre numérique portable
        • Réfractomètre numérique automatique
        • Réfractomètre numérique
        • Réfractomètre analogique
      • Rugosité
        • Mesureur de rugosité de surface
      • Température et humidité
        • Barre MFFT avec écran tactile
        • Humidimètre
        • Thermomètre de laboratoire
        • Thermomètre infrarouge
        • Testeur de point d'éclair en coupe fermée
        • Testeur de point d'éclair en tasse fermée à basse température
        • Testeur automatique de point d'éclair en coupe fermée
        • Testeur de point d'éclair Abel
        • Testeur de point d'éclair à coupe ouverte
        • Testeur de point d'éclair à coupelle ouverte basse température
        • Testeur de point de ramollissement
        • Appareil de point de fusion
        • Testeur de point de fusion avec enregistrement vidéo
        • Testeur de point de fusion
        • Testeur de point de fusion au microscope
        • Analyseur optique thermique
        • Testeur de déviation thermique
      • Mesure de tension
        • Tensiomètre superficiel Du Noüy Ring
        • Tensiomètre superficiel à plaque de Wilhelmy
      • Mesure de la taille des particules
        • Analyseur de taille de particules
        • Tamiseuse de laboratoire
    • Essais de propriétés mécaniques
      • Instruments de test de flexibilité et de déformation
        • Testeur de pliage en T
        • Testeur de courbure de mandrin cylindrique
        • Testeur de courbure à mandrin conique
        • Testeur de ventouses
        • Testeur de frappe à billes
        • Testeur de compression
        • Testeur d'écrasement des bords
        • Testeur de résistance à l'éclatement du papier
        • Testeur de résistance à l'éclatement du carton
        • Testeur de résistance à l'éclatement des textiles
        • Testeur de compression de boîte
        • Testeur d'écrasement de rouleau
        • Testeur de flexibilité de film de peinture
        • Exemples de substrats pour testeur de flexibilité Putty
        • Testeur automatique de couple de bouchons de bouteilles
      • Instruments d'essai d'impact
        • Testeur d'impact DuPont
        • Testeur d'impact à usage intensif
        • Testeur d'impact universel
        • Testeur d'impact de fléchettes tombantes
        • Testeur d'impact de panneaux de bois
      • Instruments de test d'adhérence
        • Testeur de coupe transversale d'adhérence
        • Testeur de coupe croisée d'adhérence à lame unique
        • Kit de test de règle de coupe transversale d'adhérence
        • Kit de test Adhérence X Cut
        • Testeur automatique de coupe transversale d'adhérence de peinture
        • Testeur d'adhérence entièrement automatique
        • Testeur d'adhérence automatique
        • Testeur d'adhérence au pelage
        • Testeur de coefficient de frottement COF
        • Testeur de pelage pour adhésifs
        • Testeur de boucle
        • Testeur de pelage d'adhérence
      • Instruments de test de dureté
        • Testeur de dureté de crayon
        • Testeur de dureté de crayon de bureau
        • Testeur de dureté de crayon motorisé
        • Stylo de dureté Dur-O-Test
        • Appareil de contrôle de dureté de pendule
        • Testeur de rayures automatique
        • Testeur de Mar automatique
        • Outil de grattage
        • Testeur de dureté de rebond Leeb
        • Testeur de dureté Leeb portable
        • Testeur de dureté portatif
        • Testeur de dureté de poche numérique
        • Testeur de dureté portable Rockwell & Brinell
        • Testeur de dureté Rockwell portable
        • Testeur de dureté Brinell à petite charge
        • Testeur de dureté Brinell avec écran tactile
        • Testeur de dureté Brinell
        • Testeur de dureté multiple
        • Testeur de dureté Rockwell avec écran tactile
        • Testeur de dureté Rockwell
        • Testeur de dureté superficielle Rockwell
        • Testeur de dureté Rockwell pour grand échantillon
        • Testeur de dureté plastique Rockwell
        • Testeur de dureté Vickers
        • Testeur de dureté Vickers à petite charge
        • Testeur de dureté Knoop
        • Testeur de micro-dureté avec écran tactile
        • Testeur de micro-dureté
        • Testeur d'indentation Buchholz
      • Instruments d'essai d'abrasion
        • Testeur d'abrasion humide
        • Testeur de récurage avancé à l'abrasion humide
        • Testeur d'abrasion rotatif à plate-forme unique
        • Testeur d'abrasion rotatif à double plate-forme
        • Testeur d'abrasion linéaire
        • Crockmètre manuel
        • Crockmètre électrique
        • Crockmètre rotatif électrique
        • Crockmètre rotatif
        • Crockmètre circulaire en cuir
        • Crockmètre Gakushin
        • Testeur d'abrasion et de boulochage Martindale
        • Testeur de cylindre oscillant Wyzenbeek
        • Testeur d'abrasion RCA
        • Testeur d'abrasion par chute de sable
        • Échelle de transfert chromatique en 9 étapes AATCC
        • Cartes de test de couleur à échelle de gris AATCC
        • Testeur d'abrasion avancé
      • Systèmes d'essai de traction
        • Machine de traction à colonne unique
        • Machine de traction à double colonne
      • Systèmes de test de fragilité
        • Système de test de fragilité
        • Testeur de fragilité
      • Test de lavage de la solidité des couleurs
        • Testeur de solidité des couleurs au lavage
    • Instruments d'essais climatiques
      • Équipement de test de vieillissement
        • Chambre d'essai de vieillissement UV de bureau
        • Chambre d'essai de vieillissement à la lumière UV
        • Chambre d'essai de vieillissement au xénon
        • Chambre d'essai au xénon avec système de filtre à eau
        • Chambre d'essai de vieillissement à l'arc au xénon
      • Contrôle de la corrosion
        • Chambre de brouillard salin
        • Chambre d'essai de brouillard salin
        • Chambre d'essai avancée au brouillard salin
      • Température et humidité
        • Four de laboratoire
        • Four de laboratoire antidéflagrant
        • Four à moufle
        • Four à vide de laboratoire
        • Chambre à lumière verticale
        • Bain à basse température
        • Bain-marie de laboratoire
        • Bain d'huile de laboratoire
        • Chambre d'essai climatique
        • Incubateur de bain à sec
      • Durcissement UV
        • Équipement de séchage UV
        • Radiomètre UV
    • Mélange Dispersion Broyage
      • Mélangeur de laboratoire électrique
      • Agitateur de laboratoire électrique
      • Mélangeur de laboratoire automatique avec minuterie
      • Disperseur à grande vitesse de laboratoire
      • Disperseur polyvalent de laboratoire
      • Disperseur de laboratoire avec minuterie
      • Disperseur automatique de laboratoire avec minuterie et mesure de la température
      • Disperseur et mélangeur à cisaillement élevé de laboratoire antidéflagrant
      • Moulin à paniers de laboratoire
      • Agitateur de pots de peinture à deux bras
      • Agitateur de peinture automatique
      • Agitateur de peinture pneumatique
      • Distributeur de peinture
      • Distributeur automatique de peinture
      • Agitateur orbital automatique
      • Agitateur de plaques de laboratoire
      • Grand agitateur orbital
      • Disperseur sous vide de laboratoire
      • Disperseur sous vide avancé
      • Moulin à poudre automatique
      • Moulin à poudre de bureau
      • Moulin à trois rouleaux
      • Broyeur Müller
      • Moulin à sable horizontal de laboratoire
      • Mélangeur pneumatique de laboratoire
      • Mélangeur pneumatique avec ascenseur
      • Nano-mélangeur
      • Disperseur à grande vitesse sous vide de laboratoire
      • Émulsifiant de laboratoire
      • Mélangeur de laboratoire V
    • Test des propriétés de l'encre d'impression
      • Testeur d'abrasion par frottement au solvant MEK
      • Testeur avancé d'abrasion par solvant MEK
      • Presse à épreuves d'encre
      • Épreuve d'encre d'impression
    • Instruments de test de laboratoire
      • Balances de laboratoire
      • Balances de laboratoire avec écran tactile couleur
      • Testeur Schopper Riegler
      • Testeur hydraulique Schopper Riegler
      • Testeur numérique Schopper Riegler
      • Testeur d'égouttage standard canadien
      • Testeur de point de goutte
      • Testeur de point de goutte ASTM D2265
      • Testeur automatique de point de goutte ASTM D2265
      • Balances de table
      • Balances à plate-forme
      • Testeur de perméabilité aux gaz
      • Testeur de perméabilité à la vapeur d'eau
    • Préparation scientifique des échantillons
      • Préparation d'échantillons de textiles scientifiques
        • Coupeur d'échantillons GSM
    • Instruments d'essai de textiles
      • Testeur d'abrasion MIE
      • Testeur d'abrasion universel
    • Instruments de test environnemental
      • Compteur de qualité de l'air portable
      • Échantillonneur d'air ambiant
    • Instruments de test en plastique
      • Testeur de chocs Charpy Izod
      • Testeur de chocs Charpy
      • Testeur d'impact Izod
      • Testeur d'indice de fluidité de fusion
    • Instruments de test papier
      • Testeur Schopper Riegler
      • Testeur hydraulique Schopper Riegler
      • Testeur numérique Schopper Riegler
      • Testeur d'égouttage standard canadien
      • Pied à coulisse ISO 534
      • Compteur automatique d'épaisseur de papier ISO 534
      • Testeur de résistance à l'éclatement du papier
      • Testeur de résistance à l'éclatement du carton
    • Instruments d'essai de béton
      • Marteau à rebond pour béton
      • Marteau à rebond pour béton numérique
  • Équipement
    • Disperseurs de production industrielle
      • Disperseur industriel
      • Disperseur industriel à double arbre
      • Disperseur industriel multi-arbres
      • Disperseur sous vide industriel
      • Disperseur à haute viscosité
      • Disperseur dans le réservoir
      • Disperseur sous pression dans le réservoir
      • Disperseur sous vide dans le réservoir
      • Lames de dispersion
    • Mélangeurs et agitateurs de production industrielle
      • Mélangeur dans le réservoir
    • Mélangeurs de production industrielle
      • Mélangeur en V
      • Mélangeur à double cône
    • Moulins et broyeurs de production industrielle
      • Moulin à panier industriel
      • Moulin à trois rouleaux
  • Produits chimiques
  • Nous contacter
  • À propos de nous
LIBREDEVIS
  • Accueil
  • Science and Research
  • Ph. Eur. 2.9.34 Bulk Density and Tapped Density of Powders: Essential Pharmaceutical Quality Assessment for Powder Formulation and Processing

Ph. Eur. 2.9.34 Bulk Density and Tapped Density of Powders: Essential Pharmaceutical Quality Assessment for Powder Formulation and Processing

Ph. Eur. 2.9.34 Bulk Density and Tapped Density of Powders: Essential Pharmaceutical Quality Assessment for Powder Formulation and Processing

par QUALTECH PRODUCTS INDUSTRY Science & Research / lundi, 23 juin 2025 / Publié dans Science and Research, USP Test Standards

When it comes to pharmaceutical powders, understanding their physical properties is crucial for quality control. Ph. Eur. 2.9.34 is a European Pharmacopoeia test method specifically designed to measure both the bulk density et tapped density of pharmaceutical powders. These measurements are essential for assessing powder flow properties, which directly impact manufacturing processes like tableting, capsule filling, and powder mixing.

Two transparent cylinders on a lab bench showing loose and compacted pharmaceutical powder with laboratory equipment in a pharmaceutical lab.

The test works by comparing how powder particles pack under different conditions – their natural settled state versus after mechanical tapping. This difference reveals important characteristics about how the powder will behave during processing. You can use these density values to calculate derived parameters like the Hausner ratio and Carr’s index, which provide valuable insights into powder flowability and compressibility.

Pharmaceutical manufacturers rely on this standardized method to ensure batch-to-batch consistency and predict potential processing issues before they occur. By understanding how your powder materials will flow through equipment and compact during tableting, you can optimize formulations and avoid costly manufacturing problems down the line.

Key Takeaways

  • Bulk and tapped density measurements reveal critical information about powder flow properties and compressibility for pharmaceutical manufacturing.
  • The difference between bulk and tapped density values helps predict how powders will behave during processing operations like tableting and capsule filling.
  • Consistent application of Ph. Eur. 2.9.34 ensures quality control and helps manufacturers optimize formulations before full-scale production.

Overview of Ph. Eur. 2.9.34 and Its Scope

Laboratory scene showing equipment and powder samples used to measure bulk and tapped density of pharmaceutical powders.

Ph. Eur. 2.9.34 is a standardized method for measuring bulk density and tapped density of powders in pharmaceutical applications. This test provides critical data for manufacturing processes, quality control, and formulation development.

History and Development in the European Pharmacopoeia

The Ph. Eur. 2.9.34 standard was developed as part of international harmonization efforts in pharmaceutical testing. It represents a collaboration between the European Pharmacopoeia, the United States Pharmacopeia (USP), and the Japanese Pharmacopoeia (JP) through the Pharmacopoeial Discussion Group (PDG).

This standardized method ensures consistency in powder testing across different regions and laboratories. The harmonization helps pharmaceutical companies maintain quality standards that are recognized globally.

Recent updates to Ph. Eur. 2.9.34 reflect modern manufacturing practices and improved measuring techniques. These revisions aim to increase test reliability and reproducibility across different laboratory settings.

Definition of Bulk Density and Tapped Density of Powders

Bulk density refers to the mass of powder divided by its volume, including spaces between particles. It’s measured by allowing powder to settle naturally in a container without applying external force.

Tapped density measures the same powder after mechanical tapping has compacted it. This represents how the powder behaves under vibration or movement conditions during manufacturing or shipping.

The difference between these measurements helps you calculate important powder characteristics like:

  • Carr’s Index: Indicates powder flowability
  • Hausner Ratio: Reflects powder compressibility

These values are crucial for predicting how powders will behave during tablet compression, capsule filling, and other pharmaceutical processes.

Materials and Product Types Covered by the Standard

Ph. Eur. 2.9.34 applies primarily to pharmaceutical powders used in various dosage forms. This includes active pharmaceutical ingredients (APIs), excipients, and finished powder formulations.

The standard is particularly relevant for:

  • Fine powders used in tablet and capsule manufacturing
  • Granulated materials
  • Powder blends for direct compression
  • Raw materials requiring flow assessment

Three methods are described in the standard, with Methods 1 and 3 being preferred for most applications. Method 1 uses a graduated cylinder, while Method 3 employs a volumeter for more precise measurements.

The Scott Volumeter (described in Method 2) is specifically designed for measuring bulk density of fine powders with poor flow properties.

Purpose and Specific Use of Bulk and Tapped Density Tests

Laboratory scene showing two glass cylinders with pharmaceutical powders; one with loosely settled powder and the other being compressed by a tapping device, illustrating bulk and tapped density tests.

Bulk and tapped density tests serve as critical measurements in powder analysis for pharmaceutical development. These tests help evaluate how powders settle and interact, providing essential data for quality control and manufacturing processes.

Intended Objectives in Pharmaceutical Quality Control

Bulk and tapped density tests measure a powder’s ability to pack together under different conditions. The bulk density represents the powder’s density without any mechanical force applied. In contrast, tapped density shows how tightly the powder packs after being tapped or vibrated.

These measurements help you determine the Hausner ratio et Compressibility Index (Carr’s Index), which indicate powder flowability. Good flow properties are essential for consistent tablet production.

Pharmaceutical quality control teams use these tests to:

  • Ensure batch-to-batch consistency
  • Predict filling operations in production
  • Determine proper container sizes
  • Assess the need for flow aids

The results directly impact decisions about formulation adjustments and processing parameters.

Key Applications in Pharmaceutical Manufacturing

In manufacturing, bulk and tapped density data influence several critical operations. When you design tableting processes, these measurements help predict how powders will flow into die cavities.

For blending operations, density differences between components can lead to segregation issues. Understanding these properties helps prevent uneven distribution of active ingredients.

Packaging operations rely on accurate density measurements to:

  • Calculate fill weights
  • Determine appropriate container sizes
  • Ensure consistent product volume

During scale-up from lab to production, these tests help identify potential processing challenges. Powders that show significant differences between bulk and tapped density may require special handling equipment or formulation changes.

Storage stability can also be predicted, as powders with poor flow often demonstrate greater propensity to cake or bridge during storage.

Role in Regulatory Compliance and Batch Release

Regulatory bodies like the FDA and EMA recognize bulk and tapped density tests as essential quality control measures. The European Pharmacopoeia (Ph. Eur.) specifically outlines testing procedures in chapter 2.9.34.

These tests form part of your material specifications for both raw materials and finished products. When you set acceptance criteria, you establish normal operating ranges based on:

  • Historical data
  • Process capability
  • Clinical performance requirements

For batch release, you must document these results to demonstrate consistency with approved specifications. Deviations require investigation and justification before product release.

Many pharmaceutical companies include these tests in annual product reviews to identify trends that might affect product quality. This proactive approach helps maintain compliance with current Good Manufacturing Practices (cGMP).

Principles Underlying Bulk Density and Tapped Density Determination

Two transparent cylinders filled with pharmaceutical powder, one loosely packed and the other compacted after tapping, illustrating bulk and tapped density measurement.

Powder density measurements play a crucial role in pharmaceutical formulation and quality control. These measurements provide essential information about powder flow, compressibility, and behavior during manufacturing processes.

Scientific Basis for Density Measurement

Powder density measurement relies on basic physical principles. It evaluates the relationship between mass and volume occupied by powder particles, including both the solid material and void spaces.

The scientific basis involves quantifying how particles arrange themselves within a container. When particles first settle, they create numerous air pockets, resulting in lower density.

These measurements follow fundamental mass-volume relationships where:

  • Density = Mass ÷ Volume
  • Units are typically g/mL or g/cm³
  • Volume includes both particle volume and interparticle spaces

This approach helps predict how powders will behave during pharmaceutical manufacturing processes like mixing, flow through hoppers, and tablet compression.

Distinct Concepts: Bulk Density vs. Tapped Density

Bulk density represents how powder particles naturally arrange themselves when poured into a container without any external force. It’s measured by simply dividing the powder mass by its untapped volume.

Tapped density, in contrast, measures powder density after mechanical tapping has compacted the sample. The tapping process causes particles to rearrange into more efficient packing configurations.

The relationship between these measurements reveals important powder properties:

  • Hausner Ratio = Tapped Density ÷ Bulk Density
  • Carr’s Index = [(Tapped Density – Bulk Density) ÷ Tapped Density] × 100

These values help pharmacists predict powder flowability and compressibility, which impact manufacturing decisions and final product quality.

Factors Affecting Powder Packing and Particle Arrangement

Several key factors influence how powder particles pack together, affecting both bulk and tapped densities:

Particle size and distribution: Smaller particles typically create more efficient packing arrangements, while uniform particle sizes often pack less efficiently than mixtures of different sizes.

Particle shape: Spherical particles generally flow better and pack more efficiently than irregular shapes. Needle-like or flaky particles tend to interlock, creating larger void spaces.

Surface properties: Surface roughness, electrostatic charges, and moisture content significantly impact particle interactions and packing behavior.

External factors: Container dimensions, pouring technique, and consolidation method (number of taps, tapping force) can dramatically affect measured density values.

Understanding these factors helps formulators predict and control powder behavior during pharmaceutical production.

Importance of the Standard in the Pharmaceutical Industry

Scientists in a pharmaceutical lab measuring and analyzing powders with precision instruments to ensure quality and standards.

The Ph. Eur. 2.9.34 standard for measuring bulk and tapped density provides critical data that impacts numerous aspects of pharmaceutical manufacturing. These measurements directly influence how powders behave during production processes and affect the quality of final dosage forms.

Effects on Powder Flow and Processing

Bulk and tapped density measurements help predict how pharmaceutical powders will flow through equipment. Poor flowing powders can cause inconsistent die filling in tablet presses or irregular capsule filling.

When manufacturers calculate the Hausner ratio and Compressibility Index from these density values, they gain insight into powder cohesiveness and flow properties. Powders with higher compressibility indices (>25%) typically show poorer flow characteristics.

These measurements also help you determine appropriate hopper designs and processing equipment. For instance, powders with high bulk density differences before and after tapping may require specialized feeders or vibration assistance during manufacturing.

Equipment settings and process parameters often depend on these density values, allowing you to optimize production speeds while maintaining quality.

Implications for Tableting, Encapsulation, and Product Stability

The density characteristics measured by Ph. Eur. 2.9.34 directly impact tablet hardness and dissolution profiles. Powders with certain density properties compress differently, affecting disintegration times.

During formulation development, you can use these measurements to:

  • Predict tablet weight variation
  • Estimate capsule fill weights
  • Determine appropriate compression forces
  • Select suitable excipients

Storage stability is also linked to powder density. Products made from powders with high tapped density variations may show increased moisture sensitivity or content uniformity issues over time.

For encapsulation processes, accurate density measurements help you achieve consistent fill weights and avoid under or over-filling issues that could affect drug release.

Contribution to Consistent Product Quality

Regulatory agencies expect pharmaceutical manufacturers to demonstrate consistent powder properties throughout production. The Ph. Eur. 2.9.34 standard provides a reproducible method for this quality control.

Batch-to-batch consistency is significantly improved when bulk and tapped density specifications are established and monitored. You can detect changes in raw material properties early in the manufacturing process.

These measurements also support scale-up activities from lab to production. Understanding how powder density changes with equipment size helps you maintain product quality during technology transfer.

Many quality issues in finished products can be traced back to powder density variations. By implementing routine testing using this standard, you minimize the risk of recalls and product failures related to inconsistent powder characteristics.

Test Method Applications and Representative Sample Types

A laboratory scene showing a technician measuring pharmaceutical powders in glass cylinders to demonstrate bulk and tapped density testing.

Ph. Eur. 2.9.34 provides standardized methods for measuring bulk and tapped density of pharmaceutical powders. These measurements help determine powder flow properties and compressibility, which are critical for manufacturing processes.

Examples of Powders Commonly Analyzed

The test method applies to a wide range of pharmaceutical powders. Common examples include:

  • Excipients: Lactose, microcrystalline cellulose, and starch powders used as fillers in tablet formulations
  • Active ingredients: Antibiotics, analgesics, and other medicinal compounds in powder form
  • Granulated materials: Processed powders used in direct compression tableting

Manufacturing facilities routinely test these materials to ensure consistent product quality. The method is particularly valuable for powders used in direct compression tableting, where flow properties directly impact production efficiency.

Powder behavior varies significantly based on particle size, shape, and surface characteristics. Fine powders typically show greater differences between bulk and tapped densities than coarser materials.

Case Study: Application in Active Pharmaceutical Ingredients (APIs)

In a pharmaceutical manufacturing facility, an API powder showed inconsistent tablet weight during production. Bulk and tapped density testing per Ph. Eur. 2.9.34 revealed poor flow properties with a high Hausner ratio of 1.45.

The development team implemented the following changes:

  1. Modified the particle size distribution to improve flow
  2. Added 0.5% silicon dioxide as a glidant
  3. Adjusted the hopper design to prevent bridging

Results after implementation:

  • Hausner ratio improved to 1.18
  • Tablet weight variation decreased by 60%
  • Production efficiency increased by 15%

This case demonstrates how the test method helps identify and solve manufacturing problems related to powder properties. You can use similar approaches when troubleshooting production issues in your facility.

Best Practices for Implementing and Interpreting Ph. Eur. 2.9.34

Laboratory scene showing a graduated cylinder with pharmaceutical powder and a tapping device compressing the powder to measure bulk and tapped density.

Proper implementation of the European Pharmacopoeia test method 2.9.34 for bulk and tapped density requires attention to detail and consistent technique. The following guidelines will help you achieve reliable results and meaningful interpretations when testing powder properties.

Essential Considerations for Reliable Results

When performing bulk density measurements, use a standardized method for pouring powder into the measuring vessel. The way powder is introduced affects the results significantly. Always use the same funnel design and height for consistent testing.

Control environmental conditions carefully. Temperature and humidity can influence powder flow and packing behavior. Document these conditions with each test for better result interpretation.

Sample preparation is critical. Ensure proper mixing before testing to get representative samples. Avoid excessive handling that might change powder properties through electrostatic charging or particle segregation.

Calibrate your equipment regularly. The volumeter should be checked against standard materials to verify accuracy. This includes checking graduated cylinders for proper volume markings and the tapping device for consistent operation.

Common Sources of Variability

Operator technique is one of the biggest sources of error. Train all personnel thoroughly on proper powder handling and equipment operation. Even small differences in pouring technique can lead to significant variation in results.

The physical characteristics of powders can change over time. Factors like moisture absorption, aging, or particle aggregation might affect test outcomes. Test samples promptly after preparation when possible.

Common testing errors include:

  • Inconsistent tapping force or frequency
  • Improper reading of powder volume
  • Failure to level powder surface before measurement
  • Vibration from nearby equipment affecting powder packing

Equipment selection matters too. Different models of density testers may produce slightly different results. Maintain consistency by using the same equipment for comparative studies.

Guidelines for Interpreting Density Data

Use both bulk and tapped density values to calculate the Hausner ratio (tapped density/bulk density) and Carr’s index ((tapped-bulk)/tapped × 100%). These derived values help you assess powder flowability and compressibility.

Carr’s Index (%) Flow Character Hausner Ratio
≤10 Excellent 1.00-1.11
11-15 Good 1.12-1.18
16-20 Fair 1.19-1.25
21-25 Passable 1.26-1.34
26-31 Poor 1.35-1.45
32-37 Very poor 1.46-1.59
>38 Extremely poor >1.60

Consider test results in context. A powder with “poor” flow by these standards may still be acceptable for certain applications. Compare your results with product specifications rather than relying solely on general classifications.

Always test multiple samples. Single measurements rarely capture the true variability of powder properties. Calculate the relative standard deviation to assess result consistency.

Comparison with Alternative Powder Density Test Methods

Laboratory scene showing a glass cylinder with pharmaceutical powder and a tapping device demonstrating powder density testing, with charts and lab equipment in the background.

When measuring powder density properties, several established methods exist across different standards organizations. These methods vary in their approach, equipment specifications, and application domains.

Contrast with ASTM Methods (e.g., ASTM B527, ASTM D4781)

Ph. Eur. 2.9.34 and ASTM methods differ mainly in their target materials and procedural details. ASTM B527 focuses specifically on metallic powders, using a 100 mL graduated cylinder rather than the 250 mL cylinder specified in the European Pharmacopoeia method.

ASTM D4781, designed for polymer powders, employs a different tapping mechanism with varying drop heights and frequencies. This affects the final tapped density results when compared to Ph. Eur. 2.9.34.

The reporting requirements also differ. ASTM methods typically require more detailed sample history documentation, while Ph. Eur. 2.9.34 focuses on the calculation of compressibility indices like the Hausner ratio for pharmaceutical applications.

Similarities and Differences from USP <616>

USP <616> and Ph. Eur. 2.9.34 share significant overlap since both are designed for pharmaceutical powders. Both standards include three testing methods and calculate the same compressibility parameters.

The key similarity is that both pharmacopoeias specify Method 1 (graduated cylinder), Method 2 (volumeter), and Method 3 (modified graduated cylinder). They also use identical formulas for calculating Hausner ratio and Carr’s index.

However, subtle differences exist in the tapping apparatus specifications. USP <616> allows for certain regional variations in drop height (3 mm vs. 3 ± 0.2 mm). Ph. Eur. 2.9.34 provides more detailed guidance on reading the unsettled apparent volume, particularly for powders with uneven surfaces.

Selection Criteria for Method Choice

Your choice between these methods should depend primarily on your industry requirements and material properties. For pharmaceutical applications, Ph. Eur. 2.9.34 or USP <616> is mandatory in their respective regions.

Material considerations:

  • Fine, cohesive powders → Method 2 (volumeter)
  • Free-flowing granular materials → Method 1 (graduated cylinder)
  • Small sample quantities → Method 3 (modified cylinder)

The reproducibility requirements of your testing protocol also matter. ASTM methods might be preferred when testing non-pharmaceutical materials or when comparing results with historical data obtained using these standards.

Your regulatory environment plays a decisive role. European markets require Ph. Eur. compliance, while US markets require USP compliance. For global products, you may need to validate using multiple methods to ensure regulatory acceptance.

Frequently Asked Questions

Bulk density and tapped density measurements provide essential data for pharmaceutical powder handling and processing. These tests help manufacturers ensure consistent product quality and optimize production methods.

What are the specific applications and objectives of the Ph. Eur. 2.9.34 test for bulk density and tapped density of powders?

The Ph. Eur. 2.9.34 test measures how powder particles pack together under different conditions. Bulk density shows how powder particles arrange naturally, while tapped density reveals their arrangement after mechanical tapping.

These measurements help determine powder flow properties et compressibility. They’re crucial for ensuring consistent tablet manufacturing and capsule filling operations.

The test also provides data needed to determine the Hausner ratio and Carr index, which are important indicators of powder flowability.

How does the Ph. Eur. 2.9.34 bulk density and tapped density test impact the quality control process in pharmaceutical manufacturing?

These tests serve as critical quality control checkpoints throughout production. They help ensure batch-to-batch consistency of raw materials and intermediate products.

Variations in density measurements might indicate changes in particle size, shape, or distribution that could affect final product quality. Early detection allows for adjustments before downstream processing.

Quality control teams use these measurements to verify that powders meet specifications before proceeding to tableting or encapsulation steps.

In what ways does the bulk and tapped density test conducted under Ph. Eur. 2.9.34 guide material handling and formulation in the pharma industry?

The test results directly influence equipment selection and processing parameters. Powders with poor flow properties might require specialized handling equipment or flow aids.

Formulation scientists use density data to calculate proper excipient ratios for optimal blend properties. This helps achieve target tablet hardness, disintegration times, and dissolution profiles.

Density measurements also guide packaging decisions, helping determine appropriate container sizes and fill weights for powdered products.

Can you outline best practice principles for the implementation and interpretation of the Ph. Eur. 2.9.34 bulk density and tapped density test results?

Always use standardized equipment that meets pharmacopoeial specifications. The graduated cylinders, tapping apparatus, and measurement tools should be properly calibrated.

Maintain consistent testing conditions including humidity and temperature. Environmental variations can significantly impact powder behavior and test results.

When interpreting results, consider both absolute values and comparative trends between batches. A Hausner ratio above 1.25 typically indicates poor flow properties requiring formulation adjustments.

Document all testing parameters thoroughly for traceability and reproducibility.

What materials or pharmaceutical products are most commonly subjected to the bulk density and tapped density testing as per Ph. Eur. 2.9.34?

Active pharmaceutical ingredients (APIs) routinely undergo these tests before formulation. Their flow properties significantly impact downstream processing.

Excipients like lactose, microcrystalline cellulose, and starch are tested to ensure they’ll function properly as fillers, binders, or disintegrants.

Granulated materials and powder blends require testing at intermediate manufacturing stages. This verifies that granulation or mixing processes have achieved target density properties.

Direct compression formulations are particularly dependent on proper density characteristics for successful tableting.

How does the Ph. Eur. 2.9.34 methodology for testing bulk and tapped density compare to other international pharmacopoeia standards?

The Ph. Eur. 2.9.34 methodology is harmonized with USP <616> and Japanese Pharmacopoeia methods through the Pharmacopoeial Discussion Group (PDG). This harmonization facilitates global pharmaceutical development.

All three pharmacopoeias support multiple testing methods. The European method offers three options (Methods 1, 2, and 3) that vary in cylinder volume and tapping height.

The ICH Q4B Annex 13 recognizes these harmonized procedures, allowing interchangeable use of the methods across ICH regions. This simplifies regulatory submissions for international pharmaceutical companies.

The methods share core principles but may differ slightly in specific equipment recommendations or procedural details.

A propos QUALTECH PRODUCTS INDUSTRY Science & Research

Ce que vous pouvez lire ensuite

Ph. Eur. Standard Funnel Method 2.9.36 Powder Flow: Essential Evaluation Method for Pharmaceutical Powder Flowability
ISO 2884-2:2024 Paints and Varnishes — Determination of Viscosity Using Rotational Viscometers Part 2: Essential Applications and Implementation Guidelines
ASTM D5125-10(2020)e1 Standard Test Method for Viscosity: Essential Guide for Paint Flow Measurement in Quality Control

OBTENIR UN DEVIS GRATUIT

Contactez-nous - Nous aimerions avoir de vos nouvelles

Obtenez dès maintenant des informations sur les produits, le support technique, le service client, les ventes, les relations publiques, les services professionnels et les partenaires. Vous pouvez également nous faire part de vos commentaires sur notre site Web.
Merci de bien vouloir remplir ce formulaire. Un de nos spécialistes répondra à votre demande sous peu. Vous pouvez également nous contacter via les coordonnées de la société aux États-Unis, en Australie ou au Royaume-Uni.

    Veuillez noter que nous respectons votre vie privée et gardons vos coordonnées strictement confidentielles.

    ASTM
    ANSI
    bsi
    CEI
    AATCC
    TÜV
    ISO
    VACARME

    © 1978 - 2025 INDUSTRIE DES PRODUITS QUALTECH Conditions d'utilisation termes et conditions Biscuits Nous contacter

    HAUT
    Ce site Web utilise des cookies pour améliorer votre expérience, cependant, nous respectons votre vie privée et les cookies ne collectent que des données anonymes. Nous respectons votre vie privée et vous pouvez vous désinscrire, si vous le souhaitez.
    Paramètres des cookiesAccepter tout
    Gérer le consentement

    Aperçu de la confidentialité

    Ce site Web utilise des cookies pour améliorer votre expérience lorsque vous naviguez sur le site Web. Parmi ceux-ci, les cookies classés comme nécessaires sont stockés sur votre navigateur car ils sont essentiels au fonctionnement des fonctionnalités de base du site Web. Nous utilisons également des cookies tiers qui nous aident à analyser et à comprendre comment vous utilisez ce site Web. Ces cookies ne seront stockés dans votre navigateur qu'avec votre consentement. Vous avez également la possibilité de refuser ces cookies. Mais la désactivation de certains de ces cookies peut affecter votre expérience de navigation.
    Nécessaire
    Toujours activé
    Les cookies nécessaires sont absolument essentiels au bon fonctionnement du site Web. Ces cookies assurent les fonctionnalités de base et les éléments de sécurité du site Web, de manière anonyme.
    BiscuitDuréeDescription
    cookielawinfo-checkbox-analytics11 moisCe cookie est défini par le plugin GDPR Cookie Consent. Le cookie est utilisé pour stocker le consentement de l'utilisateur pour les cookies de la catégorie « Analytics ».
    cookielawinfo-checkbox-fonctionnel11 moisLe cookie est défini par le consentement aux cookies du RGPD pour enregistrer le consentement de l'utilisateur pour les cookies de la catégorie « Fonctionnel ».
    cookielawinfo-case à cocher-nécessaire11 moisCe cookie est défini par le plugin GDPR Cookie Consent. Les cookies sont utilisés pour stocker le consentement de l'utilisateur pour les cookies dans la catégorie « Nécessaire ».
    cookielawinfo-checkbox-autres11 moisCe cookie est défini par le plugin GDPR Cookie Consent. Le cookie est utilisé pour stocker le consentement de l'utilisateur pour les cookies de la catégorie "Autre".
    cookielawinfo-checkbox-performance11 moisCe cookie est défini par le plugin GDPR Cookie Consent. Le cookie est utilisé pour stocker le consentement de l'utilisateur pour les cookies de la catégorie « Performance ».
    visualisé_cookie_policy11 moisLe cookie est défini par le plugin GDPR Cookie Consent et est utilisé pour stocker si l'utilisateur a consenti ou non à l'utilisation de cookies. Il ne stocke aucune donnée personnelle.
    Fonctionnel
    Les cookies fonctionnels aident à exécuter certaines fonctionnalités telles que le partage du contenu du site Web sur les plateformes de médias sociaux, la collecte de commentaires et d'autres fonctionnalités tierces.
    Performance
    Les cookies de performance sont utilisés pour comprendre et analyser les principaux indices de performance du site Web, ce qui contribue à offrir une meilleure expérience utilisateur aux visiteurs.
    Analytique
    Les cookies analytiques sont utilisés pour comprendre comment les visiteurs interagissent avec le site Web. Ces cookies aident à fournir des informations sur les mesures telles que le nombre de visiteurs, le taux de rebond, la source du trafic, etc.
    Publicité
    Les cookies publicitaires sont utilisés pour fournir aux visiteurs des publicités et des campagnes marketing pertinentes. Ces cookies suivent les visiteurs sur les sites Web et collectent des informations pour proposer des publicités personnalisées.
    Autres
    Les autres cookies non classés sont ceux qui sont en cours d'analyse et qui n'ont pas encore été classés dans une catégorie.
    Enregistrer & appliquer
    fr_FRFrançais
    en_USEnglish da_DKDansk de_DEDeutsch elΕλληνικά es_ESEspañol es_MXEspañol de México fiSuomi fr_CAFrançais du Canada it_ITItaliano nl_NLNederlands sv_SESvenska pt_PTPortuguês fr_FRFrançais
    en_US English
    en_US English
    da_DK Dansk
    de_DE Deutsch
    el Ελληνικά
    es_ES Español
    es_MX Español de México
    fi Suomi
    fr_FR Français
    fr_CA Français du Canada
    it_IT Italiano
    nl_NL Nederlands
    sv_SE Svenska
    pt_PT Português