ASTM D1894
Standard Test Method for Static and Kinetic Coefficients of Friction of Plastic Film and Sheeting
ASTM D1894 is a standard test method used to determine the static (µs) and kinetic (µk) coefficients of friction of plastic film and sheeting. These coefficients are important for understanding the slip properties of plastic films, which are of wide interest in packaging applications. The test results can be used for quality control purposes in film production and for predicting the performance of films in various applications.
Scope
This test method covers the determination of the coefficients of starting and sliding friction of plastic film and sheeting when sliding over itself or over other substances at specified test conditions. The procedure permits the use of a stationary sled with a moving plane, or a moving sled with a stationary plane. Both procedures yield the same coefficients of friction values for a given sample.
Apparatus
The apparatus for ASTM D1894 consists of the following:
A test frame with a crosshead speed of 150 mm/min (5.9 in/min)
A sled with a smooth, flat surface
A plane with a smooth, flat surface
A weight to provide the desired normal force
A load cell to measure the friction force
Procedure
The test procedure is as follows:
Clean the sled and plane surfaces.
Secure the film specimen to the sled.
Place the sled on the plane and apply the desired normal force.
Start the crosshead and record the initial peak force for static friction.
Record the average force during sliding motion over 127 mm (5 in) of travel for kinetic friction.
Calculations
The static coefficient of friction (µs) is calculated as follows:
µs = Fs / N
Fs is the initial peak force for static friction (N)
N is the normal force (N)
The kinetic coefficient of friction (µk) is calculated as follows:
µk = Fk / N
Fk is the average force during sliding motion for kinetic friction (N)
N is the normal force (N)
Report
The test report should include the following information:
Sample identification
Test conditions (speed, normal force)
Static coefficient of friction (µs)
Kinetic coefficient of friction (µk)
Precisão
The precision of ASTM D1894 is as follows:
The repeatability (within-laboratory precision) is ±0.10 for both µs and µk.
The reproducibility (between-laboratory precision) is ±0.15 for both µs and µk.
Todos os nossos instrumentos de teste, equipamentos de teste e máquinas de produção são projetados e projetados de acordo com padrões de teste internacionais reconhecidos, incluindo ASTM, AATCC, CIE, DIN EN ISO, MIL, Ford, Renault, AS NZS, TAPPI e muitos mais.
Todos os nossos produtos são cuidadosamente calibrados para garantir a alta precisão esperada de sua pesquisa e de suas etapas de gerenciamento de qualidade e testes de amostras.
Além disso, estamos sempre aqui para auxiliar com serviços adicionais de calibração em nossos Centros de Calibração.
Apoiar
Atendimento ao cliente em todas as etapas e fidelidade aos nossos clientes, atendimento profissional e entrega de produtos, instrumentos e máquinas da melhor qualidade são quatro de nossas principais prioridades para garantir que você e suas equipes de especialistas ficarão entusiasmados e felizes com a qualidade confiável de nossos produtos, instrumentos e máquinas. A Indústria de Produtos Qualtech desenvolveu e instituiu um sistema de qualidade e possui certificação ISO 9001:2000. Estamos comprometidos em avaliar e implementar melhorias de qualidade em todos os nossos processos de pesquisa e produção, garantindo que “a qualidade seja entregue ao seu negócio”. Por favor, peça suporte às nossas simpáticas equipes, mais informações, detalhes e serviços disponíveis contratados para trazer valores reais para você como nosso importante cliente.