Have you ever wondered how we measure light and its interaction with materials? CIE 15.2, developed by the International Commission on Illumination (CIE), is a fundamental standard that defines photometric quantities using the V(λ) weighting function. This standard is essential for accurately measuring how materials transmit or scatter light, providing the foundation for haze and transmission tests used across multiple industries.

When you look through a foggy window or examine the clarity of packaging materials, you’re observing properties that can be precisely measured using principles from CIE 15.2. The standard defines how human visual perception relates to physical measurements of light, establishing the mathematical framework for quantifying transparency, translucency, and haziness. These measurements help manufacturers ensure product quality and consistency in industries ranging from automotive and architecture to packaging and optical materials.
Key Takeaways
- CIE 15.2 establishes the V(λ) weighting function that matches light measurements to human visual perception.
- The standard provides the foundation for haze and transmission tests used to evaluate material clarity and light-scattering properties.
- Proper application of CIE 15.2 principles ensures consistent quality control for transparent and translucent materials across industries.
Purpose and Scope of CIE 15.2

CIE 15.2 is a foundational document published by the International Commission on Illumination that defines standard methods for colorimetry. This technical report establishes the framework for measuring and quantifying color in a scientifically consistent way.
The primary purpose of CIE 15.2 is to provide standardized procedures for color measurement that ensure results are comparable across different laboratories and equipment. It defines important photometric quantities using the V(λ) weighting function, which models the human eye’s sensitivity to different wavelengths of light.
In testing applications, CIE 15.2 is particularly valuable for haze and transmission measurements. These tests help you determine how much light passes through materials and how it scatters.
Key components of CIE 15.2 include:
- Definitions of standard illuminants (light sources)
- Standard colorimetric observers (1931 and 1964)
- Calculation methods for tristimulus values
- Chromaticity coordinates for various illuminants
When you need to evaluate transparent or translucent materials, CIE 15.2 provides the mathematical foundation for meaningful measurements. This applies to plastics, glass, films, and coatings.
The document serves as a reference for many ASTM test methods that require standardized color and light transmission evaluations. By following these standards, you can achieve reliable and reproducible test results when measuring optical properties.
Photometric Quantities Defined by CIE 15.2

The CIE 15.2 standard establishes key photometric quantities used in optical measurements including haze and transmission tests. These definitions standardize how light is measured in relation to human visual perception.
V(λ) Weighting and Human Visual Response
V(λ) weighting represents how the human eye responds to different wavelengths of light. This function peaks at 555 nm (green-yellow light) where our eyes are most sensitive. At this peak wavelength, 1 watt of radiant power equals 683 lumens of luminous flux.
The human eye’s sensitivity drops significantly toward both blue and red ends of the spectrum. This natural response curve must be accounted for in optical measurements.
When you perform haze or transmission tests, the V(λ) function helps convert radiometric quantities (physical light measurements) into photometric quantities (how humans perceive light). This ensures test results correlate with visual perception.
Without V(λ) weighting, measurements would fail to represent how materials appear to human observers.
Key Photometric Parameters
Luminous flux (measured in lumens) represents the total light output weighted by the V(λ) function. This differs from radiant flux, which measures total energy without considering visual response.
Illuminance (measured in lux) indicates how much light falls on a surface. This parameter is crucial in transmission testing to ensure consistent test conditions.
Luminance (measured in candelas per square meter) measures the brightness of a surface as perceived by human observers. This is particularly important in haze evaluation.
Transmittance represents the ratio of transmitted to incident light, weighted by V(λ). When measuring material clarity, this provides results that match human visual assessment.
You should use these photometric quantities when evaluating material appearance properties like clarity, haze, and light transmission.
Specific Use in Haze and Transmission Tests

The CIE 15.2 standard provides essential photometric definitions that form the foundation for accurate optical measurements in materials testing. These definitions are particularly relevant when evaluating the transparency and light-scattering properties of materials.
Application in ASTM Haze Methods
ASTM haze test methods like D1003 rely on CIE 15.2’s standardized photometric quantities to ensure consistent measurements. When you perform these tests, you’re measuring the percentage of transmitted light that deviates from the incident beam by more than 2.5 degrees.
The V(λ) weighting function defined in CIE 15.2 adjusts light measurements to match human visual perception. This means test results reflect how the human eye would perceive haziness, not just raw physical measurements.
Common materials tested include plastics, films, glass, and transparent packaging. The test helps you determine:
- Total transmittance: Overall light passing through
- Diffuse transmittance: Scattered light
- Klarhed: Direct light transmission
Equipment calibration for these tests must reference CIE standard illuminants (typically D65) as specified in the CIE document.
Why CIE 15.2 Is Critical to Test Accuracy
Without CIE 15.2’s photometric definitions, haze and transmission measurements would vary significantly between laboratories and instruments. The standard ensures you get comparable results regardless of testing location or equipment manufacturer.
The V(λ) function specifically addresses the varying sensitivity of human vision across different wavelengths. This weighting is crucial because it transforms physical light measurements into perceptually relevant values.
Key benefits of applying CIE 15.2 include:
- Standardized illuminants that represent real-world lighting conditions
- Consistent calculation methods for color values
- Clear definitions for luminance and illuminance
When interpreting test results, you can be confident they correlate with actual visual perception of material quality. This makes the data more relevant for product development and quality control.
General Principles Behind the Standard

Det CIE 15 standard establishes fundamental principles for colorimetry that enable accurate measurement and communication of color information across different instruments and laboratories.
Standardization of Light Measurement
CIE 15.2 defines how photometric quantities should be measured using the V(λ) weighting function. This function models the human eye’s sensitivity to different wavelengths of light, peaking at 555 nm (yellow-green region).
For haze and transmission tests, this standardization is crucial because it ensures measurements reflect what humans actually see rather than just physical light quantities.
The standard defines specific illuminants (like Standard Illuminant D65 to represent average daylight) to ensure consistency in testing conditions.
Two standard observers are defined: the CIE 1931 Standard Observer (2° field of view) and the CIE 1964 Supplementary Standard Observer (10° field of view). These are used depending on the viewing angle required for specific applications.
Ensuring Reproducibility and Comparability
The standard specifies exact mathematical formulas and procedures for calculating tristimulus values, chromaticity coordinates, and color differences. This mathematical foundation makes measurements objective and repeatable.
Test geometries are standardized to control how light interacts with materials. This includes specific angles for illumination and viewing during transmission and haze testing.
Calibration procedures ensure different instruments produce comparable results. Without these standards, measurements from different laboratories would be impossible to compare meaningfully.
The standard includes recommendations for illuminating and viewing conditions to minimize variables that could affect test results.
By following CIE 15.2 guidelines, manufacturers can verify product quality across different facilities and ensure compliance with specifications regardless of where testing occurs.
Industries and Materials Relevant to CIE 15.2

CIE 15.2 defines photometric quantities that are critical for haze and transmission testing across multiple industries. These standards provide consistent methodology for measuring how light interacts with various transparent and translucent materials.
Plastics and Transparent Films
Polymer manufacturers rely on CIE 15.2 standards to evaluate the optical properties of plastic films and sheets. You’ll find these measurements particularly important for packaging materials where clarity impacts consumer perception of contained products.
Clear polycarbonate, polyethylene, and PET films require precise haze measurements to ensure quality control. Medical packaging demands exceptionally transparent materials with quantifiable optical properties.
Food packaging manufacturers use these standards to ensure their materials provide adequate protection while maintaining product visibility. Haze measurements help you determine if a plastic film will appear clear or cloudy to consumers.
Agricultural films also benefit from these measurements, as light transmission directly impacts crop growth in greenhouse applications.
Glass and Architectural Applications
Building and construction industries apply CIE 15.2 standards when evaluating glazing materials. You need accurate light transmission data to determine energy efficiency and visibility characteristics of windows.
Architects specify glass based on these measurements to achieve desired aesthetics and functional performance. Low-E glass requires precise photometric evaluation to balance visible light transmission with thermal insulation properties.
Safety glass manufacturers use these standards to ensure consistent optical quality after lamination or tempering processes. Museum display cases need specialized glass with quantifiable UV filtering properties.
Building energy codes often reference CIE-based measurements to establish minimum performance requirements for daylighting and energy efficiency in commercial structures.
Automotive and Display Industries
Vehicle manufacturers apply CIE 15.2 standards to windshields, windows, and displays. You must ensure driver visibility meets safety requirements through standardized photometric measurements.
Head-up displays (HUDs) depend on precise optical characteristics to project information clearly onto windshields. Automotive interior displays use these standards to maintain readability in various lighting conditions.
Electronic device manufacturers rely on these measurements for screens and protective covers. Mobile phones, tablets, and monitors need consistent optical performance across production batches.
Aircraft manufacturers apply these standards to cockpit windows and displays where clarity directly impacts safety. Medical imaging displays require exceptional optical properties with minimal haze to ensure diagnostic accuracy.
Interpreting Results and Implications

Understanding CIE 15.2 test results requires careful analysis of photometric data. The interpretation directly affects product acceptance and human perception considerations.
Impact on Product Quality and Compliance
Test results from CIE 15.2 serve as critical quality indicators for transparent and translucent materials. When V(λ) weighting is applied to transmission measurements, you can determine if products meet industry specifications for light transmission and haze.
Materials with high haze values may indicate poor manufacturing processes or degradation over time. For automotive glass, results below compliance thresholds can lead to rejection during quality control.
You should compare your test data against historical benchmarks to identify trends or anomalies. Many industries have specific pass/fail criteria:
Industry | Typical Transmission Requirement | Maximum Haze Allowed |
---|---|---|
Automotive | >70% | <2% |
Optical displays | >90% | <0.5% |
Arkitektonisk | >65% | <3% |
Dokumentation af resultater bør omfatte både rådata og beregnede værdier for at sikre sporbarhed.
Implikationer for visuel opfattelse
V(λ)-vægtningsfunktionen i CIE 15.2 korrelerer tæt med menneskelig visuel opfattelse, hvilket gør testresultaterne relevante for virkelige anvendelser.
Produkter med dårlige testresultater skaber ofte visuelt ubehag for brugerne. Høje disværdier kan forårsage:
- Reduceret synlighed gennem materialer
- Forvrænget farveopfattelse
- Øget øjenbelastning ved længerevarende brug
Du bør overveje, hvordan varierende lysforhold kan påvirke opfattelsen ud over det almindelige testmiljø. Et materiale, der fungerer godt under laboratorieforhold, kan stadig skabe problemer med synligheden i direkte sollys.
Aldersrelaterede ændringer i det menneskelige syn komplicerer yderligere fortolkningen, da ældre brugere kan være mere følsomme over for sløring. Ved design af sikkerhedskritiske applikationer bør man anvende strengere standarder end minimumskravene.
Brugeraccepttest supplerer ofte fotometriske målinger for at validere, at teknisk overholdelse af reglerne resulterer i tilfredsstillende visuel ydeevne.
Bedste praksis for implementering

Korrekt implementering af CIE 15.2 kolorimetristandarder kræver opmærksomhed på både udstyrsspecifikationer og miljøforhold. Korrekt anvendelse sikrer nøjagtige og reproducerbare fotometriske målinger, der er afgørende for dis- og transmissionstest.
Standardiseret instrumentering
Når du vælger instrumenter til fotometriske målinger i henhold til CIE 15.2, bør du bruge spektrofotometre eller kolorimetre, der overholder CIE-anbefalingerDisse instrumenter skal nøjagtigt inkorporere V(λ)-vægtningsfunktionen, som modellerer det menneskelige øjes følsomhed.
Kalibrer dit udstyr regelmæssigt ved hjælp af certificerede referencestandarder. Dette hjælper med at opretholde målenøjagtigheden over tid.
Ved måling af dis skal du sørge for, at dit instrument kan skelne mellem diffus og spejlende transmission. De fleste moderne spektrofotometre tilbyder specifikke tilstande til dette formål.
Bekræft, at dit instruments geometri stemmer overens med CIE's anbefalinger (0°/diffus eller 8°/diffus). Denne geometrispecifikation påvirker, hvordan lys interagerer med din prøve.
Dokumenter alle instrumentindstillinger i dine testrapporter, herunder bølgelængdeområde, båndbredde og måletilstand.
Kritisk evaluering af testbetingelser
Rumforholdene påvirker fotometriske målinger betydeligt. Oprethold et kontrolleret miljø med en temperatur på 23 °C ± 1 °C og en relativ luftfugtighed på 50% ± 5%.
Eliminer spredt lys i dit testområde. Selv små mængder omgivende lys kan forvrænge aflæsningerne, især for meget transparente prøver.
Håndter prøverne forsigtigt for at undgå fingeraftryk, ridser eller kontaminering. Brug handsker og prøveholdere, der er designet til optisk testning.
Standardisere prøveforberedelsesteknikkerSørg for en ensartet tykkelse og overfladekvalitet for film og ark.
Lad prøverne opnå rumforhold i mindst 24 timer før testning. Dette minimerer målevariationer på grund af temperatur- eller fugtighedspåvirkninger.
Udfør målinger i triplikat på forskellige prøvesteder for at tage højde for materialevariabilitet og sikre repræsentative resultater.
Sammenligning med lignende fotometriske standarder
Det CIE 15.2 Standarden giver et grundlag for fotometriske målinger ved hjælp af V(λ)-vægtning, der adskiller sig fra, men supplerer, andre internationale standarder. Adskillige testorganisationer har udviklet deres egne tilgange til måling af lys- og farveegenskaber.
Forskelle mellem ASTM- og ISO-metoder
ASTM-metoder fokuserer typisk på materialespecifikke anvendelser af fotometriske principper, mens CIE 15.2 etablerer den grundlæggende videnskab bag disse målinger. For eksempel refererer ASTM D1003 til måling af dis CIE's V(λ)-funktion, men tilføjer specifikke testgeometrier og retningslinjer for prøveforberedelse.
ISO-standarder anvender ofte CIE's grundlæggende principper, men udvider dem til bestemte brancher. ISO 13468 for transmissionsmålinger inkorporerer CIE's fotometriske principper, men tilføjer specifikke procedurer til plastmaterialer.
Den vigtigste forskel er, at CIE 15.2 definerer de kolorimetriske observatørfunktioner og lysstofspecifikationer, som andre standarder refererer til. Mens ASTM- og ISO-metoder giver detaljerede testprocedurer, leverer CIE den underliggende matematiske ramme.
Supplerende brug med yderligere standarder
CIE 15.2 fungerer bedst, når den bruges sammen med applikationsspecifikke standarder. Du kan kombinere den med ASTM E308 til beregning af kolorimetriske værdier for at skabe omfattende testprotokoller.
CIE-standarden angiver de spektrale effektfordelinger for standardbelysningsstoffer (D65, A osv.), der refereres til i andre testmetoder. Når du udfører transmissions- eller distest, skal du bruge både de grundlæggende CIE-definitioner og de proceduremæssige detaljer fra ASTM- eller ISO-metoder.
Mange brancher kræver flere standarder for fuldstændig overholdelse. For eksempel kan test af bilglas kræve CIE 15.2 for de fotometriske definitioner, ASTM D1003 for proceduren for måling af dis og ISO 9050 for soltransmissionsegenskaber.
Denne multistandardtilgang sikrer både videnskabelig validitet og praktisk anvendelighed i dine testprotokoller.
Ofte stillede spørgsmål
CIE 15.2 giver vigtig vejledning til fotometriske målinger i dis- og transmissionstests. Disse standarder er med til at sikre ensartede og pålidelige resultater på tværs af forskellige testmiljøer og applikationer.
Hvad er målene med ASTM-testmetoden relateret til CIE 15.2 med hensyn til evaluering af fotometriske størrelser?
Det primære mål er at etablere standardiserede metoder til måling af, hvordan materialer transmitterer, spreder eller absorberer lys. Denne standardisering hjælper med at evaluere materialers klarhed, gennemsigtighed og optiske egenskaber med ensartethed.
Testmetoden sigter mod at kvantificere visuel opfattelse ved hjælp af V(λ)-vægtning, som modellerer det menneskelige øjes følsomhed over for forskellige bølgelængder af lys. Dette muliggør målinger, der korrelerer med den menneskelige visuelle oplevelse.
Et andet centralt mål er at levere repeterbare og reproducerbare resultater, der kan sammenlignes på tværs af forskellige laboratorier og testfaciliteter verden over.
Kan du beskrive de generelle principper, der styrer CIE 15.2-standarden for dis- og transmissionstest?
CIE 15.2-standarden er baseret på princippet om, at den menneskelige visuelle opfattelse varierer med bølgelængden. V(λ)-funktionen repræsenterer den almindelige observatørs følsomhed over for lys ved forskellige bølgelængder.
Lystransmissionsmålinger vægtes i henhold til denne V(λ)-funktion for at matche den menneskelige visuelle opfattelse. Det betyder, at bølgelængder, som det menneskelige øje er mere følsomt over for, har større indflydelse på den endelige måling.
Standarden definerer specifikke belysningsforhold, synsgeometrier og måleteknikker for at sikre konsistens. Disse kontrollerede forhold muliggør meningsfulde sammenligninger mellem forskellige materialer og produkter.
Hvorfor er CIE 15.2-standarden vigtig for industrier, og hvilke anvendelser har den inden for materialeprøvning?
Standarden er afgørende for producenter af transparente og gennemskinnelige materialer som glas, plast og film. Den hjælper med at sikre, at produkterne opfylder visuel kvalitet krav og lovgivningsmæssige specifikationer.
I bilindustrien evaluerer disse tests forruder og vinduer for klarhed og sikkerhed. Dårlige optiske egenskaber kan forårsage visuelle forvrængninger, der kan påvirke førerens udsyn.
For emballagematerialer hjælper standarden med at måle den gennemsigtighed, der er nødvendig for produktpræsentation. Fødevare-, drikkevare- og detailemballage kræver ofte specifikke niveauer af klarhed og lysgennemgang.
Byggebranchen bruger disse målinger, når de vælger rudematerialer. Energieffektivitet, visuel komfort og æstetiske overvejelser afhænger alle af nøjagtig fotometrisk testning.
Hvordan påvirker resultaterne af den fotometriske CIE 15.2-test beslutningstagningen inden for produktudvikling og kvalitetskontrol?
Testresultaterne har direkte indflydelse materialevalg i produktdesignfaserne. Ingeniører kan vælge materialer, der giver den optimale balance mellem klarhed, lysdiffusion og andre optiske egenskaber.
Kvalitetskontrolafdelinger bruger disse målinger som beståelses-/fejlkriterier. Produkter, der ikke opfylder de etablerede fotometriske specifikationer, kan identificeres og fjernes fra produktionen.
Dataene hjælper producenter med at optimere procesforholdene. Temperatur, tryk og andre variabler i produktionen kan justeres for at opnå de ønskede optiske egenskaber.
Disse målinger understøtter også overholdelse af branchestandarder og -forskrifter. Mange bygningsreglementer, bilsikkerhedsstandarder og forbrugerproduktforskrifter specificerer minimumskriterier for fotometrisk ydeevne.
Hvad er nogle bedste fremgangsmåder for at sikre nøjagtige resultater ved implementering af den fotometriske testmetode CIE 15.2?
Regelmæssig kalibrering af dit fotometriske udstyr er afgørende. Brug certificerede referencematerialer med kendte værdier for at verificere dit systems nøjagtighed.
Kontroller testmiljøet omhyggeligt. Omgivende lys, temperaturudsving og støv kan alle påvirke målenøjagtigheden.
Prøverne skal forberedes ensartet i henhold til standardspecifikationerne. Prøvetykkelse, overfladeforberedelse og håndteringsprocedurer skal forblive ensartede på tværs af testene.
Grundig træning af operatørerne i både de teoretiske og praktiske aspekter af testen. Forståelse af principperne bag målingerne hjælper teknikerne med at genkende, hvornår resultaterne kan være tvivlsomme.
Dokumentér alle testbetingelser og proceduremæssige detaljer. Disse oplysninger er afgørende for fejlfinding af uventede resultater og sikring af testens reproducerbarhed.
På hvilke måder adskiller CIE 15.2-standarden sig fra andre fotometriske testmetoder, og hvorfor kan den ene vælges frem for en anden?
CIE 15.2 inkorporerer specifikt V(λ)-vægtningsfunktionen, mens nogle andre metoder måler absolut lystransmission uden denne justering af det menneskelige syn. Når korrelation med visuel opfattelse er vigtig, foretrækkes CIE 15.2.
Standarden fokuserer på integrerede målinger på tværs af det synlige spektrum. Andre metoder kan analysere specifikke bølgelængder eller spektrale områder separat.
CIE 15.2 er internationalt anerkendt, hvilket gør den ideel til globale markeder. Regionale standarder kan foretrækkes ved test af produkter i henhold til specifikke lokale regler.
Udstyrskravene til CIE 15.2-testning kan være mere sofistikerede end til simplere transmissionstests. Budgetbegrænsninger eller applikationsbehov kan føre til valg af alternative metoder.